Application and Analysis Chilling Ceiling Combined with Displacement Ventilation System in Office Buildings

Article Preview

Abstract:

Using the method of computational fluid dynamics (CFD), numerically simulates office building with chilling ceiling /displacement ventilation (CC/DV) and analyzes indoor airflow velocity field, temperature field and thermal stratification height of the building. Consider that the CC/DV system can improve indoor air quality and save energy. And the CC/DV system could solve many constraints of displacement ventilation system. when the cooling load is large, due to the limit of air supply and temperature supply the displacement ventilation system can not be used, but the CC/DV system could well satisfied the requirement of body. The CC/DV system also has the problem of lower thermal stratification height because the chilling ceiling has a lower temperature.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 160-162)

Pages:

294-300

Citation:

Online since:

November 2010

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Hodder S G, Loveday D L, Parsons K C, Taki A H. Thermal comfort in chilled ceiling and displacement ventilation environment: vertical radiant temperature asymmetry effects. Energy and Buildings, 1998, 27(2): 167-173.

DOI: 10.1016/s0378-7788(97)00038-8

Google Scholar

[2] Novoselac A, Srebric J. A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems. Energy and Buildings, 2002, 34: 497-509.

DOI: 10.1016/s0378-7788(01)00134-7

Google Scholar

[3] Sodec F. Economic viability of cooling ceiling systems[J]. Energy and Buildings, 1999 (30), 195-201.

DOI: 10.1016/s0378-7788(98)00087-5

Google Scholar

[4] Niu J, Kooi J V D, Ree H V D. Energy saving possibilities with cooled-ceiling system [J]. Energy and Buildings . 1995 (23): 147-158.

DOI: 10.1016/0378-7788(95)00937-x

Google Scholar

[5] Novo selac A, Srebric J. A critical review on the performance and design of combined cooled ceiling and displacement ventilation [J]. Energy and Buildings . 2002 (34), 497-509.

DOI: 10.1016/s0378-7788(01)00134-7

Google Scholar

[6] Matson U. Comparison of the modeling and the experimental results on concentrations of ultra-fine particles indoors. Building and Environment, 2005, 40(7): 996-1002.

DOI: 10.1016/j.buildenv.2004.09.001

Google Scholar

[7] Yu Haiming, Yang Guozhong. fluid dynamics [M]. Haerbin: MAPS PRESS. (2008).

Google Scholar

[8] Tao wenquan, Numerical heat transfer (Second edition), [M], Xi'an: Xi'AN JIAOTONG UNIVERSITY PRESS, (2001).

Google Scholar

[9] Zhao B, Li X, Zhang Z, Huang D. Comparison of diffusion characteristics of aerosol particles in different ventilated rooms by numerical method. ASHRAE Trans, 2004, 110: 88-95.

Google Scholar

[10] Zhao B, Zhang Y, Li X, Yang X, Huang D. Comparison of indoor aerosol particle concentration and deposition in different ventilated rooms by numerical method. Building and Environment, 2004, 39(1): 1-8.

DOI: 10.1016/j.buildenv.2003.08.002

Google Scholar

[11] Lau J, Chen Q. Floor-supply displacement ventilation for workshops. Building and Environment, 2007, 42(4): 1718-1730.

DOI: 10.1016/j.buildenv.2006.01.016

Google Scholar

[12] Huang Xiang, Yu Hongwei, Chen Shu'ai. Comparison of Different Types of Ventilation in Combined System of Chilled Ceiling to Investigate the Effect of Indoor Air Quality [J]. Contamination Control & Air-Condition Technology, 2008. 6(2)18-23.

Google Scholar

[13] Yu Songbo, Tu Guangbei, Na Yanling. Application and analysis of displacement ventilation in office buildings [J]. Heating Ventilating & Air conditioning, 2003 (3)99-101.

Google Scholar

[14] Ma Renmin, Lian Zhiwei. Some question in displacement ventilation [J]. Heating Ventilating & Air conditioning, 2000 (4)18-22.

Google Scholar

[15] Yu Songbo. Influence of cooled ceiling on displacement ventilation system: CFD study . [ Master's degree paper]. Tian Jin: Tianjin University. (2003).

Google Scholar

[16] Wang Jinsheng, Long Weiding. Met hodology of avoiding co ndensation and downdraft in displacement ventilation plus cooling ceiling system[J]. Heating Ventilating & Air conditioning, 2009 (1)27-31.

Google Scholar