Research on Performance of Resisting Foundation Displacement of High Voltage Electricity Transmission Tower in Mining Subsidence Area

Article Preview

Abstract:

The performance of resisting foundation displacement of a typical single return circuit transmission tower under all kinds of load conditions including foundation horizontal displacement, foundation vertical uneven downward displacement was analyzed by finite element modeling. Results showed that stability failure of single steel angle represents tower’s limit state under foundation displacement. And the corresponding foundation displacement limits were calculated. Results indicate that foundation pull condition is more dangerous than press condition. Under complex foundation displacement conditions, foundation horizontal displacement is primary factor leading to stability failure of towers. Under foundation press condition and pull condition, wind load is primary factor. Result also indicates that, tower does not fail when foundation displacements are smaller than 1.25% (under foundation press condition and pull condition) or 0.5% (under single foundation sink condition) of tower root distance.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 168-170)

Pages:

2308-2314

Citation:

Online since:

December 2010

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Fengchun Li, Guo Guangli, Den Kezhong. Mining Safety & Environmental Protection,2002,29(2):18-20(in Chinese).

Google Scholar

[2] Mengmin Kuang. Guangdong Electric Power,2002,15(1):67-69(in Chinese).

Google Scholar

[3] Jianqiang Zhang, Kun Yang, Yudong Wang, et al. Power System Technology,2006,30(2):20-34(in Chinese).

Google Scholar

[4] Zhenhua Shi.Shanxi Electric Power,1997,17(3):18-20(in Chinese).

Google Scholar

[5] Bin Zhen, Wenbin Guo, Huabin Cai. Modern Mining Industry. 2009(1):86-89(in Chinese).

Google Scholar

[6] Fengli Yang, Jingbo Yang, Junke Han, et al. Proceedings of the CSEE, 2009, 29(1): 100-106(in Chinese).

Google Scholar

[7] Guanglin Yuan, Yunfei Zhang, Jianwen Chen, et al. Power System Technology, 2010(1): 214-218(in Chinese).

Google Scholar

[8] Guanglin Yuan, Gengyu Yang, Yunfei Zhang. Journal of China Coal Society, 2009, 34(8): 1043-1047(in Chinese).

Google Scholar

[9] The State Economic and Trade Commission of the People's Republic of China. 2001. Operating code for overhead transmission line, Beijing (in Chinese).

Google Scholar

[10] The State Economic and Trade Commission of the People's Republic of China. 2002. Technical Regulation of design for tower and pole structures of overhead transmission line. Beijing(in Chinese).

Google Scholar

[11] The State Economic and Trade Commission of the People's Republic of China. 1999. Technical code for designing 110-500kV overhead transmission line. Beijing (in Chinese).

Google Scholar

[12] American Society of Civil Engineers(ASCE). 1997. Design of latticed steel transmission structures. New York.

Google Scholar

[13] European Committee for Standardization. 2005. Design of steel structures-part 3-1: towers, masts and chimneys-towers and masts.

DOI: 10.3403/30126882

Google Scholar