The Research of Light Pulses on the Inactivation of Escherichia Coli

Article Preview

Abstract:

In this paper, E. coli as experimental subjects ,by changing the input voltage, bacterial concentration, turbidity and pH to study the impact that the use intense white light on the inactivation of E. coli in medium surface. The results showed that: light pulses had a strong effect on lethal E. coli, with the input voltage increasing, the inactivation rate increased. The input voltage is 2500v as an appropriate experimental condition, that satisfy both conservation of energy and a better inactivation .The inactivation rate and the logarithm of livability of E. coli rising with the bacterial concentration increasing, when the light flashes six times, the medium surface almost be killed. Turbidity affect to the inactivation of E. coli, with the turbidity increasing, the effect of the inactivation gradually weakened. When ph was changed, the impact of pulsed light on E. coli inactivation was less .The effect of inactivation achieve the best level when pH was 6.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 183-185)

Pages:

663-667

Citation:

Online since:

January 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Lagunas-solar M C, Pina C, MacDonald J D, et al. Development of pulsed UV light processes for surface fungal disinfection of fresh fruits. Journal of Food Protection. 2006, 69(2): 376~384.

DOI: 10.4315/0362-028x-69.2.376

Google Scholar

[2] Marquenie D, Michiels C W, Van Impe J F, et al. Pulsed white light in combination with UV-C and heat to reduce storage rot of strawberry. Postharvest Biology and Technology. 2003, 28: 455~461.

DOI: 10.1016/s0925-5214(02)00214-4

Google Scholar

[3] Marquenie D, Geeraerd A H, Lammertyn J, et al. Combinations of pulsed white light and UV-C or mild heat treatment to inactivate conidia of Botrytis cinerea and Monilia fructigena. International Journal of Food Microbiology. 2003, 85: 185~196.

DOI: 10.1016/s0168-1605(02)00538-x

Google Scholar

[4] Huffman D E, Slifko T R, Salisbury K, et al. Inactivation of bacteria, virus and Cryptosporidium by a point-of-use device using pulsed broad spectrum white light. Water Research. 2000, 34(9): 2491~2498.

DOI: 10.1016/s0043-1354(00)00014-2

Google Scholar

[5] Wekhof, A. Disinfection with flash lamps. PDA J. Pharmaceut. Sci. Technol. 2000, 4(3): 264~267.

Google Scholar

[6] Wang T, MacGregor J G, Anderson J G, et al. Pulsed ultra-violet inactivation spectrum of Escherichia coli. Water Research. 2005, 39: 2921~2925.

DOI: 10.1016/j.watres.2005.04.067

Google Scholar

[7] Dunn, J., 1996. Pulsed light and pulsed electric field for foods and eggs. Poultry Science 75, 1133–1136.

DOI: 10.3382/ps.0751133

Google Scholar