On Fuzzy Logic in Hydroturbine Temperature Fault Diagnosis in HESS

Abstract:

Article Preview

Hydroturbine temperature fault diagnosis in hydro-electrical simulation system (HESS) through a way of fuzzy logic is studied in this paper. Failure reasons of temperature-related subsystems of hydroturbine are firstly discussed, and fault diagnosis principles, thereby, are determined. Fuzzy logic, including membership function, fuzzy matrix and so on, are then studied and used in the fault diagnosis process. Finally, the fuzzy logic fault diagnosis is testified by examples and experiments to be acceptable in efficiency and accuracy.

Info:

Periodical:

Advanced Materials Research (Volumes 225-226)

Edited by:

Helen Zhang, Gang Shen and David Jin

Pages:

39-42

DOI:

10.4028/www.scientific.net/AMR.225-226.39

Citation:

Y. Xu and Z. Wang, "On Fuzzy Logic in Hydroturbine Temperature Fault Diagnosis in HESS", Advanced Materials Research, Vols. 225-226, pp. 39-42, 2011

Online since:

April 2011

Authors:

Export:

Price:

$35.00

In order to see related information, you need to Login.

In order to see related information, you need to Login.