Appliance of 3-D Composite Layered Element in RCC Dam

Abstract:

Article Preview

A numerical calculation method and a new type element of EFM for the simulation of the RCC dams is presented. It takes into account the more relevant features of RCC, such as the transversely isotropic, the layered character, the strength unequal to tension and compress and the discontinuities. A 3D model of RCC Dam, built in South-West of China, is used to perform the corresponding analyses. The result shows the location of third height to dam heel in upstream dam will be crack between layers. So it is very dangerous for arch dam. In the the locations of third height to dam toe and dam crest of the downstream of the dam will occur the stresses concentration, so some of engineer measures must be adopted to avoid the damage.

Info:

Periodical:

Advanced Materials Research (Volumes 243-249)

Edited by:

Chaohe Chen, Yong Huang and Guangfan Li

Pages:

4619-4622

DOI:

10.4028/www.scientific.net/AMR.243-249.4619

Citation:

R. Gao "Appliance of 3-D Composite Layered Element in RCC Dam", Advanced Materials Research, Vols. 243-249, pp. 4619-4622, 2011

Online since:

May 2011

Authors:

Export:

Price:

$35.00

In order to see related information, you need to Login.

In order to see related information, you need to Login.