According to the existed theory foundation, the authors made a simulated analysis on mechanical properties of a connection between steel reinforced concrete filled with steel tube column and steel beam, using ABAQUS, which is a finite element software. The authors established element model reasonably, and got load- displacement curve in different axial compression ratios. According to the result, with the increasing of axial compression ratio, the elements' limit bearing capacity reduces significantly.