Influence of Hoop Coefficient on Dynamic Response of Railway Bridge Protective Frame under Impact Load

Article Preview

Abstract:

The paper analyzes that hoop coefficients of the concrete-filled steel tube influence on dynamic response of the railway bridge height limit protective frame under impact load by using ANSYS/LS-DYNA. Change hoop coefficient of the concrete-filled steel tube structure by changing steel tube wall thickness. The result shows that with increase of steel tube wall thickness, the average impact force of protective frame will increase and the displacement and deformation will reduce, and protective frame can resist greater impact load. It will provide the reference for design of railway bridge height limit protective frame.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 291-294)

Pages:

1321-1326

Citation:

Online since:

July 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Railway transportation safety protection ordinance[s], 2005, 4

Google Scholar

[2] Lu Hui. New advances in the research on dynamic performance of concrete-filled steel tubes [J]. World Earthquake Engineering, 2007, 23(4): 119-128

Google Scholar

[3] He Tao, Yang Jing, Jin Xin. ANSYS 10.0/LS-DYNA Nonlinear finite element analysis example tutorial guide [M]. Mechanical industry press, 2007, 1

Google Scholar

[4] Zhong Shantong. The unified theory of CFST members--- research and application [M]. Tsinghua university press, 2006, 8

Google Scholar

[5] Wang Rui, Li Zhu, Ren Gouping, Zhang Shanyuan. Experimental study and numerical simulation of the dynamic response of concrete filled steel tubes under lateral impact load [J]. China Civil Engineering Journal, 2007, 40(10): 34-39

Google Scholar

[6] Wen Yuanyuan, Liu Yangling. Experimental study of the fixed-freely-supported steel pipe concrete under the lateral impact[J]. Building Technology, 2009,40(11): 1045-1047

Google Scholar

[7] Huang Pingming, Zhang Zhengwen, Liu Guolin, Liu Zhuguo. The Analysis of the Hooping Mechanism of CFST [J]. Journal of Xi'an Highway University, 2001,21(4): 43-45

Google Scholar

[8] Ricles J M, Peng S W, Lu L W. Seismic behavior of composite concrete filled steel tube column-wide flange beam moment connections [J]. Journal of Structural Engineering ASCE, 2004, 130(2): 223-232

DOI: 10.1061/(asce)0733-9445(2004)130:2(223)

Google Scholar

[9] Hardika M S, Gardner N J. Behavior of concrete-filled hollow structural section beam columns to seismic shear displacements [J]. ACI Structural Journal, 2004, 101(1): 39-46

DOI: 10.14359/12996

Google Scholar