Research on the Pollution Diffusion Regularity near Sewage Outlet Areas in Yuncheng Reach of the Fen River

Article Preview

Abstract:

The purpose of this paper is to find the pollution diffusion regularity near sewage outlet area of Yuncheng reach of the Fen River. A 2-D water hydrodynamic and quality model was used to simulate flow field, the water quality and contamination dispersion. The parameters of the model were calibrated with measured data of the water depth, flow and water quality in Yuncheng reach of the Fen River. According to the simulated result, the total area of pollution belt with 19 sewage outlets is 8.89km2 in normal year. And 3.89% of the reach has a worse water quality than V class in standard. The percentage of V and Ⅳ Class of water is 69.17% and 26.94%.In dry year, the total area of pollution belt with 19 sewage outlets is 8.89km2.The percentage of inferior V, V and Ⅳ Class of water is 27.80%, 69.46% and 2.74%. It was shown by the simulated results that the concentration gradient decreases with increasing distance to the outlets and the dilution and dispersion of pollutants was enhanced by a greater river flow.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Pages:

2430-2436

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Boxall J B. Locating outlets on meandering channels to optimize transverse mixing [A]. LI Guifen. XXIX IAHR Congress Proceedings [C]. Beijing: Tsinghua University Press, (2001).

Google Scholar

[2] LUO Yi-sheng. One dimensional hydrodynamic and water quality simultaneous measure and typical mixing zone observation in the Three Gorges Reservoir [R]. 1-03-01-1, Wuhan: Bureau of Hydrology, Hydraulic Committee of Yangzi River, 2002. (in Chinese).

Google Scholar

[3] WEN Cheng Liu, Wei Bo Chen. Nobuaki Kimura. Impact of phosphorus load reduction on water quality in a stratified reservoir-eutrophication modeling study[J]. Environmental Monitoring and Assessment, 2009, 159(4): 393-406.

DOI: 10.1007/s10661-008-0637-3

Google Scholar

[4] GONG Chun-sheng, YAOQi, FAN Cheng-xin ZHAO Di-hua, 2-D plane flow-water quality-bed sediment pollutant coupled model [J]. Journal of Hydraulic Engineering, 2006, 37(2): 205-209.

Google Scholar

[5] FENG Min-quan, HU Fang, WU Bo, DANG Zhi-liang The dispersion law about the near outlet pollution in Han River (Ankang) area[J]. Northwest university journal (natural science edition) , 2009, 39(05): 887-890.

Google Scholar

[6] WANG Xu, LI Kefeng, Li Ran, HAO Hongsheng, TUO Youcai, Water quality simulation of coupled effect of multiple sewage outlets in urban river reach[J] Journal of Wuhan University(Industrial Science) , 2008, 41(02): 24-27.

Google Scholar

[7] DUAN De-hong WANG Gen-xia WANG Pin Rao Shan-shan. 2-D Steady model with computer simulation[J]. Journal of Lanzhou Jiaotong University(natural science edition) , 2004, 23(6): 9-11.

Google Scholar

[8] HUANG Cheng, ZHONG Cheng-hua, DENG Chun-guang, etc. Characteristics of contamination zone around discharge outlet after water storage of Three Gorges Reservoir at water level of139m: A case study on Yunyang sewage treatment plant. [J]. Water Resource Protection, 2007, 23(2): 20-24.

DOI: 10.1109/icitbs.2015.211

Google Scholar

[9] HUANG Cheng, DENG Chun-guang, LI Xiao, XING Zhi-guo, BAI Yang . Characteristics of Pollution Zone around Drain Outlet of Fuling Sewage Treatment Plant. [J]. China water and wastewater, 2009, 25(2): 105-108.

Google Scholar