Abstract:

Aiming at the inadequacies of the existing liquid injection mechanism, a novel pulsed micro-injection technology based on an amplification piezoelectric actuator (APA) was presented. The mechanics of the micro-injection was investigated. The theoretical model among the parameters of flow velocity, orifice’s dimension, amplitude and rising time of the pulsed signal was established. A micro-injection experimental system was established. The injection pressure out of the orifice was measured. Results show this novel micro-injection technology is feasible, and future development of the novel injection systems is possible.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 403-408)

Pages:

3748-3752

Citation:

Online since:

November 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Voelker, R. Eradication efforts need needle-free delivery. JAMA. 1999, 281(20): 1879-1881.

DOI: 10.1001/jama.281.20.1879-jmn0526-2-1

Google Scholar

[2] Samir Mitragotri. Current status and future prospects of needle-free liquid jet injectors. Nature Reviews, Drug Discovery, 2006, 5: 543-548.

DOI: 10.1038/nrd2076

Google Scholar

[3] Anubhav Arora, Itzhak Hakim, Joy Baxter, etl. Needle-free delivery of macromolecules across the skin by nanoliter-volume pulsed microjets. PNAS, 2007, 104(11): 4255-4260.

DOI: 10.1073/pnas.0700182104

Google Scholar

[4] YAN Ke, JIN Long, XU Zhike, etl. Research on Technique and Application of Piezoelectric Stack Actuator. Micromotors. 2008, 41(5): 80-82.

Google Scholar

[5] Frank C, R. Leletty, F. Barillot, O. Sosnicki. Amplified piezoelectric actuators: static & dynamic applications. Ferroelectrics. 2007, 351: 3-14.

DOI: 10.1080/00150190701351865

Google Scholar

[6] A.B. Baker, J.E. Sanders. Fluid mechanics analysis of a spring-loaded jet injector, IEEE Trans. Biomed. Eng. 1999, 46(2): 235-242.

DOI: 10.1109/10.740886

Google Scholar

[7] Zen liqun. Development of needle-free injection. Hangzhou, Zhejiang University, (2008).

Google Scholar

[8] Joy Schramm-Baxter, Samir Mitragotri. Needle-free jet injections: dependence of jet penetration dispersion in the skin on jet power. Journal of Controlled Release. 2004, 97: 527- 535.

DOI: 10.1016/j.jconrel.2004.04.006

Google Scholar

[9] Joy Baxter, Samir Mitragotri. Jet-induced skin puncture and its impact on needle-free jet injections: Experimental studies and a predictive model. Journal of Controlled Release. 2005, 106: 361-373.

DOI: 10.1016/j.jconrel.2005.05.023

Google Scholar