Research and Design on the High-Voltage Line Harmonic Detection Based on a New Method

Article Preview

Abstract:

In order to measure the high-voltage transmission line voltage harmonic signal directly and timely, a new approach based on field intensity method is put forward, solving the problems of getting the high-voltage transmission line voltage harmonic signal indirectly by using the traditional methods. Through the establishment of the field intensity method to get voltage signal mathematical model so as to prove its correctness in theory, besides, the actual measurement circuit of harmonic detector is designed to verify the correctness of the theory. High-voltage transmission line harmonic detector can easily detect voltage harmonic content of the high-voltage line

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 424-425)

Pages:

260-264

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Su Fuhang. Environmental protection of high voltage transmission [M]. Beijing: China Water Power Press, 1998, 5.

Google Scholar

[2] Ni Guangzheng, Qian Xiuying. Numerical Computation Of Electromagnetic Field [M]. Beijing: Higher-Education-Press, (1996).

Google Scholar

[3] Miguel O B C Melo, Luiz C A Fonseca, Electric and magnetic fields of compact transmission lines[J], IEEE Trans on PWRD. 1999, 14(1): 200-(2004).

Google Scholar

[4] Technical regulations on environmental impact assessment of electromagnetic radiation produced by 500 KV ultrahigh voltage transmission and transfer power engineering . People's Republic of China Environmental Protection Industry Standard, HJ/T 24—(1998).

Google Scholar

[5] Xiang Zhongqing, Jiang Daoqian. LU Yin. Calculation of electric field intensity on the SU trace of transmission lines based on the surface charge simulation method[J]. Hunan Electric Power, 2007. 27(1): 5-8.

Google Scholar

[6] Research and design on the High-voltage line Non-contact Harmonic Detection Based on Field Intensity Method. Proceeding of the IASTED International Conference , Modelling , Simulation, and Identification(MSI2009) October, 12-14, 2009 Beijing, China.

Google Scholar

[7] Xiao Jianhua, The Design of the Power Harmonics Detection System, Jishou University Journal, Vol. 21, No. 3.

Google Scholar

[8] Zhang Jinbo. Wang Jun. Fan Meirong. Feng Yuanyuan. Design of wireless phase detector for high voltage power transmission lines. Power Automation Equipment, (2005).

Google Scholar

[9] Zhang Jinbo, Study and realization of wireless phase measurement for high voltage electric power line, Chinese Journal of Scientific Instrument, Nov. (2006).

Google Scholar

[10] Zhang Jinbo, Design of Wireless Phase Detector for High Voltage Transmission Lines, HIGH VOLTAGE ENGINEERING, Aug. (2006).

Google Scholar