Study of Voltage Stability in Grid-Connected Large Wind Farms

Article Preview

Abstract:

Squirrel-cage induction generator (SCIG), as its structural and economic advantages, has been widely utilized in large wind farms in China. However, the large wind farm composed of induction generators will cause obvious problems to the power system stability due to the dependency on reactive power. At the same time, Doubly-fed induction generator (DFIG), as a new type of wind turbine generator, has excellent dynamic characteristics for operation of wind farms. With the increase in penetration of wind power in power systems, more and more wind farms will use both SCIG and DFIG. In this case, the dynamic characteristic of wind farm on power systems is becoming an important issue especially in terms of the voltage stability. This article is to show by means of simulations the dynamic performance of wind farm linked to power system under the circumstances of network disturbances. Furthermore, the interaction between the SCIGs and DFIGs has also been investigated. A detailed model of wind farms is presented through the plat root of MATLAB/SIMULINK. The simulation results demonstrate that the DFIG applications will largely improve the dynamic performance of wind farm in certain conditions, if the DFIGs could be applied reasonably, the voltage stability of the wind farm will be largely improved and even low voltage ride through(LVRT) characteristic of SCIGs, which may be a good solution to reduce the high dependence of costly reactive power compensation equipment(Some flexible AC transmission systems devices like SVC, STATCOM) to some extent.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 433-440)

Pages:

1794-1801

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] The Global Wind Energy Council, GWEC Latest News, 2010, GWEC publishes 2009 annual report, April, 2010, [Online], http: /www. gwec. net.

Google Scholar

[2] Claudio L. Souza et. al., Power System Transient Stability Analysis Including Synchronous and Induction Generator, IEEE Porto Power Tech Proceedings, Vol. 2, p.6, (2001).

DOI: 10.1109/ptc.2001.964711

Google Scholar

[3] Muller S, Deicke M, De Donker RW. Doubly fed induction generator systems for wind turbines. IEEE Ind Appl Mag.

DOI: 10.1109/2943.999610

Google Scholar

[4] S MüllER, M DEICKE, RIK W DE DONCKER, Doubly fed induction generator systems for wind turbines[J], IEEE Industry Applications Magazine, 2002, 8(3): 26-32.

DOI: 10.1109/2943.999610

Google Scholar

[5] Ya-feng, Huang; Gan-gui, Yan; Chu-yan, Chao; Gang, Mu; Zhen-qing, Zhang; Fei, Xu; Cheng-xin, Zhang. Mining and utilization of reactive power capability of doubly fed induction generator systems for wind turbines sustainable Power Generation and Supply, 2009. SUPERGEN '09. International Conferenceon 6-7 April 2009 Page(s): 1 - 5 Digital Object Identifier 10. 1109/SUPERGEN. 2009. 5348117.

DOI: 10.1109/supergen.2009.5348117

Google Scholar

[6] S. M. Muyeen, Mohd. Hasan Ali, R. Takahashi, T. Murata, J. Tamura, Y.

Google Scholar

[7] Tomaki, A. Sakahara, and E. Sasano, A Comparative Study on Transient Stability Analysis of Wind Turbine Generator System Using Different Drive Train Models, IET-Proceedings on Renewable Power Generation(IFT-RPG). Vol. 1, No. 2, pp.131-141. lune. (2007).

DOI: 10.1049/iet-rpg:20060030

Google Scholar

[8] Fengquan Zhou,Géza Joós.Voltage Stability in Weak Connection Wind Farms[J].IPEMC 2006:196-200.

Google Scholar

[9] W. Freitas, Jose C. M. Vieira, A. Morelato, Luiz C. P. da Silva, Vivaldo F. da Costa, and Flavio A. B. Lemos, Comparative analysis between synchronous and induction machines for distributed generation applications, IEEE Trans. on Power System, Vol. 21, no. 1, pp.301-311, (2006).

DOI: 10.1109/tpwrs.2005.860931

Google Scholar

[10] S.M. Muyeen, Mohd. Hasan Ali, Rion Takahashi, Toshiaki Murata, and Junji Tamura, Transient Stability Enhancement of Wind Generator by a New Logical Pitch Controller, IEEE Trans. PE., Vol. 126-B, No. 08, pp.742-752, (2006).

DOI: 10.1541/ieejpes.126.742

Google Scholar

[11] E. O. N. GmbH. (2003, Aug. ) Grid code for high and extra high voltage. [Online]. Available: http: /www. eon-netz. com.

Google Scholar

[12] ZHU Wu, CAO Rui-fa, improved low voltage ride-through of wind farm using STATCOM and pitch control" Power Electronics and Motion Control Conference, 2009. IPEMC , 09. IEEE 6th International.

DOI: 10.1109/ipemc.2009.5157771

Google Scholar