Static Balancing of Mechanical Systems Used in Medical Engineering Field – Continuous Balancing

Article Preview

Abstract:

In medical field are used many categories of mechanical systems, from simple mechanisms to the complex mechatronic systems. Present paper is focused to those mechanical systems that are working in vertical plane by supporting loads or by lifting weights. The targets are both patients and medical workers. Paper is proposing some new devices and mechanisms for supporting the weights that are hanged to the ceiling. These mechanical systems are called too with zero-stiffness because the balancing force does not depend to elongation of elastic system. For all the presented solutions the balancing of the weight forces will be done by using the elastic forces of torsion spiral springs and cylindrical helical springs with straight characteristics. The balancing is made exactly for all positions throughout the work field.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 463-464)

Pages:

890-894

Citation:

Online since:

February 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] L. Ciupitu, I. Simionescu. Static Balancing of Mechanical Systems used in Medical Engineering Field – Approximate Balancing. In: Romanian Journal of Technical Science (SISOM '05, Bucharest, Romania, May 19-20, 2005) pp.296-303.

DOI: 10.4028/www.scientific.net/amr.463-464.890

Google Scholar

[2] P. Cowan, K. Dennison, R. H. Nathan, J. Skorecki. Floating arm supports: Preliminary trail and further development. Proceedings of the Fourth World Congress on the Theory of Machines and Mechanisms, Newcastle-Upon-Tyne, England, 1975, pp.815-820.

Google Scholar

[3] B. L. Davis, P. R. Cavanagh. Simulating reduced gravity: a review of biomechanical issues pertaining to human locomotion. In: Aviat. Space Environ. Med., 1993, 64, pp.557-566.

Google Scholar

[4] H. P. Greene. Load compensator for spring counter-weighting mechanism. United States Patent 5, 400, 721, (1995).

Google Scholar

[5] J. L. Herder. Energy-free Systems. Theory, conception, and design of statically balanced spring mechanisms. PhD Thesis, Technische Universiteit Delft, The Nederland, ISBN 90-370-0192-0, (2001).

Google Scholar

[6] S. Hirose, M. Imazato, Y. Kudo, Y. Umetani. Internally-balanced magnet unit. In: Advanced Robotics. 1986, 1(3), pp.225-242.

DOI: 10.1163/156855386x00139

Google Scholar

[7] Š. Segla. Optimization of Statical Balancing of a Lift Mechanism. In: Acta Mechanica Slovaca, ISSN 1335-2393, 2004, 3-C/2004, pp.153-160.

Google Scholar

[8] I. Simionescu, L. Ciupitu. The Static Balancing of Industrial Robot Arms. Part II: Continuous Balancing. In: Mechanism and Machine Theory, 2000, 35(9), pp.1299-1311.

DOI: 10.1016/s0094-114x(99)00068-3

Google Scholar

[9] ** (Therapeutic Products Directorate - Canada). Medical Device Alert 109: Incidents involving patient lifts. March 20, 1997, http: /www. hc-sc. gc. ca/hpfb-dgpsa/tpd-dpt/alert_109_e. html, Last access 2005-04-15.

Google Scholar