Improvement Measures and Evaluation of Energy Efficiency of Air Conditioning

Article Preview

Abstract:

Air conditioning and refrigeration equipment are more and more widely applied, It’s energy efficiency proportion of total energy consumption is growing. To evaluate energy efficiency and apply high grade energy efficiency of air conditioning , that can bring considerable economic benefits and improve energy-saving initiative for the enterprises. This has great practical significance to realize Chinese energy-saving task. In this paper the air conditioning energy efficiency ratio(EER), seasonal energy efficiency ratio(SEER) and integrated part load value(IPLV) are proposed and analyzed, Many evalution methods are put forword to provide appropriate evaluation criteria for enterprise, and the energy-saving measures on the different assessment criteria are also put forward, It has some guiding significance to improve the efficiency of air conditioning and refrigeration equipment.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 468-471)

Pages:

1989-1992

Citation:

Online since:

February 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] GB/T 18430.1-2001 Water Chiller(Heat pump) Using the Vapor Compression Cycle and Using for Industry and Commerce and Similarity Use [S]. Beijing: The Standards Press of China ,2002( In Chinese).

Google Scholar

[2] American Society of Heating, Refrigeration and Air-C-onditioning Engineers,Inc. ASHRAE Stand 90.1-2001 Energy Standard for Buildings Except Low-Rise Resi-dential Buildings[S]. 1791 Tullie Circle N.E. Atlanta, Georgia,30329,USA,2003.

Google Scholar

[3] GB 12021.3-2010 The Minimum Allowable Value Of The Energy Efficiency and Energy Efficiency Grades For Room Air Conditioners[S]. Beijing: The Standards Press of China ,2010(In Chinese).

Google Scholar

[4] Ji J, Pei G, Chow, et al. 2005 Performance of multi-functional domestic beat-pump system[C]. Appl. Energy, 80:307-26.

Google Scholar

[5] Beian A. Advanced Engineering Thermodynamics. New York: John Wiley, 1988.

Google Scholar

[6] Chen Zeshao, Jiang Bin, Shi Min, et al. Analysis of Factors Influencing the COP of Heat-pump and Energy- saving Methods[J]. Fluid Machinery, 2007, 35(1):65-68.(In Chinese)

Google Scholar

[7] ANSI/ARI Standard 210/240-2008 Unitary Air-condition-ing and Air-Source Heat Pump Eqipment.

Google Scholar

[8] Brian P Dougherty, James J Filliben, Ana Ivelisse Aviles. Central Air Conditioner Test Procedure Public Workshop:A Technical Discussion On New Defaults for National Institute of Standards and Technology Gaithersburg, MD 20899.

Google Scholar

[9] Li Shaobin, Cao Yong . Ways of improving SEER of room air conditioner based on testing and calculation methods in American standard[J]. Refrigeration and Air-Conditioning, 2010,10(1):60-64.(In Chinese).

Google Scholar

[10] Liu Shengchun, Ma Yitai, Lu Wei. Analysis About EER and SEER of Air Conditioner[J]. Journal of Tianjin University, 2006,39(9):1088-1092.(In Chinese)

Google Scholar