The Discharge Characteristic Analysis and the Simulation of Axial Piston Pumps

Article Preview

Abstract:

This paper analyses the influence of geometric parameter on the flow pulsation, calculates its flow pulsation coefficient theoretically,then takes account of the influence of leakage rate on flow pulsation of the plunger pumps, and simulates 5-ram pump to nine-ram pump with its actual parameters to calculate its instantaneous delivery and autual flow pulsation coefficient . The conclusion can be drawn that its actual flow pulse coefficient considering leakage flow is obviously larger than theoretical instantaneous delivery, so we should minimize the leakage.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 490-495)

Pages:

3018-3022

Citation:

Online since:

March 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Na Zhongqing, Research on Instantaneous Delivery of Axial Piston Pumps[J], Journal of Lanzhou University of Science and Engineering, 2004,vol30(l): 56-59.

Google Scholar

[2] Liu Liguo, Calculation and Analysis on Discharge Characteristic of Piston Pumps [J]. Hydraulic Pressure and Pneumatic, 2004(4): 58-59.

Google Scholar

[3] Xu Shijun, Research on Flow Pulsation Axial Piston Pumps, Machinery Manufacture and Research, 2007, 36(3): 39-41, 43.

Google Scholar

[4] Na Chenglie, Liu Shulian, Na Yanqing etc. Research and Emulation on Flow Pulsation of Axial Piston Pumps. Machine Tool and Hydraulic Pressure, 2000, supplementary issue, 16-18.