On-Line Monitoring of Charge Unit by Using Fiber Bragg Grating Temperature Sensors

Article Preview

Abstract:

The charge unit supply power when the power is cut off. It has been the necessary components in every type of substations to ensure the continuous operations of electric relays, automatic devices and circuit breakers. By using contacting electrical insulating Fiber Bragg Grating temperature sensor, the monitored equipment can be measured and controlled under the safe temperature. The temperatures of three fans and environment have been surveyed since June 6, 2010, in the charge unit of Yanjin substation’s main control room. The real-time monitoring of 24-hours indicates that the temperature changes in the range of 1°C. At the long-term of 479 days, the average daily minimum temperature range of three fans is 12.48°C, and the maximum range is 23.07°C. The maximum temperature is 39.14°C on April 30, 2011, and the minimum temperature is 23.98°C on January 10, 2011. The daily average of ambient temperature range is 12.04 °C, the maximum temperature is 38.38 °C on July 16, 2010, and the minimum temperature is 26.34 °C on January 9, 2011. The maximum difference between the temperature of fan and the ambient temperature is 7.60 °C on October 23, 2010. According to the relevant standards and monitoring results, the maximum threshold of fan temperature is defined to 85°C, and the threshold of temperature rise is 20°C.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 503-504)

Pages:

1672-1678

Citation:

Online since:

April 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Mengxin Zhao, Weicheng Yu, China Electric Power Education, 2008, in Chinese.

Google Scholar

[2] Suhua Wang, Xiangyang Peng, Xiao Han, et al, Power System Protection and Control, 2010, 38(17): 179-182, in Chinese.

Google Scholar

[3] Chuang Li, Yimo Zhang, Ronggui Zhao, Lijing Li, Fiber Grating: the theory technology and sense application. (2005).

Google Scholar

[4] Zaixuan Zhang, Insoo S Kim, Jianfeng Wang, et a1. SPIE, 2001, 4540: 386-390.

Google Scholar

[5] Guoping Yang , Yuanyan Zhi , Yinlu Dai , Electric Switchgear, 2006, 44(5). -39-41, in Chinese.

Google Scholar

[6] DL/T459-2000. Specifictions of D. C supply cabinet in power system(S).

Google Scholar

[7] National Technical Committee 6 on Fire Controlling of Standardization Administration of China. GB/T 21197—2007 Line type optical fiber heat detectors [S]. BeOing: China Standards Press, 2007, in Chinese.

Google Scholar