Optimum Design of an Internal 8-Electrode Electrical Capacitance Tomography Sensor Array

Article Preview

Abstract:

This paper introduced an optimum design method of sensor array suitable for electrical capacitance tomography (ECT) based on high AC excitation voltage. The sensor parameters of electrode span and length were optimized in turn, and a sensor model for testing was fabricated according to optimal objects. The image reconstruction experimental resultants of grain distribution indicated that high quality images could be reconstructed by the sensor model. This proved the optimal design method of ECT sensor given in this paper was feasible and the parameters were also credible.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

84-87

Citation:

Online since:

April 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] W.Q. Yang, Design of electrical capacitance tomography sensors [J]. Meas. Sci. Technol. 21(2010).

Google Scholar

[2] H. Yan, H. Xu, F.Q. Shao, Finite Element Modeling and Orthogonal Optimizing of Capacitance Concentration Sensor for Two Phase Flow [J] J. Northeastern University, 20(1999), 33-36.

Google Scholar

[3] W.H. Wang, L.F. Zhang, X.M. Zhu. Optimum Design of Array Electrode for ECT System [J]. J. Tianjin University, Vol. 36 No. 307-310 2003. 03.

Google Scholar

[4] F.Q. Shao, Y.L. GAO, Y.G. ZHANG, etc., Analysis and Optimization of ECT Sensor Using Orthogonal Experiment with Interaction of Factors [J] J. Northeastern University, 240(2003)103-106.

Google Scholar

[5] X.Y. Dong, S. Liu Shi, J.T. Li, etc, The Optimizing Design of Capacitance Tomography Sensors Based on Uniform Design and LS-SVM[J],J. Basic Science and Engineering 14(2006).

Google Scholar

[6] Z.H. Guo Zhiheng, F.Q. Shao Fuqun, D.C. Lu, Optimum Design of Interior Electrode Sensors for ECT System[J] Chinese Journal of Sensors and Actuators, 21(2008).

Google Scholar

[7] X.N. Wen, H.X. Wang, L. Hu, Parameter Optimization of 3-Dimensional ECT Electrode Array Based on ANSYS[J] Chinese J. Sensors and Actuators, 20(2007), 1639-42.

Google Scholar

[8] D.C. Lu, F.Q. Shao, Z.H. Guo. A high voltage method for measuring low capacitance for tomography[J]. Rev. Sci. Instrum. 80(2009).

Google Scholar

[9] D.C. Lu, F.Q. Shao, Z.H. Guo. Inspection of low capacitance by high voltage method[J] Chinese Journal of Scientific Instrument, 30(2009), 1448-52.

Google Scholar