Modeling and Thermal Performance Analysis of Parabolic trough Solar Field with Single-Axis Tracked

Article Preview

Abstract:

In this paper, a model of parabolic trough solar field with single-axis tracked was developed based on detailed mathematical derivation. A software tool is also developed for its performance calculation. By the model and software, the direct solar irradiation (DNI) intercepted by the collectors and the thermal output can be obtained for a given solar field under different tracking mode. To obtain the characters of the solar field performance with different tracking modes and regions, the annual performance of the solar field is evaluated for different sites in China such as Beijing, Lhasa. Besides that, the effect of the space between collector rows on thermal output of a solar field is also discussed.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 512-515)

Pages:

101-108

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhai Hui , Dai Yanjun, Wu Jingyi , etal. Research on arrangement problem of large scale flat plane/evaculated tube solar collector array. Acta Energiae Solaris Sinica.. 2008, 29(5): 564-568 (in Chinese)

Google Scholar

[2] Runsheng Tang, Wenfeng Gao, Yamei Yu, Hua Chen. Optimal tilt-angles of all-glass evacuated tube solar collectors. Energy 34 (2009) 1387–1395.

DOI: 10.1016/j.energy.2009.06.014

Google Scholar

[3] Tang Runsheng, Wu Tong. Optimal tilt-angles for solar collectors used in China. Applied Energy 2004;73(3):239–48.

DOI: 10.1016/j.apenergy.2004.01.003

Google Scholar

[4] Shu N, Kameda N, Kishida Y, Sonoda H. Experimental and theoretical study on the optimal tilt angle of photovoltaic panels. Journal of Asian Architecture and Building Engineering 2006;5:399–405.

DOI: 10.3130/jaabe.5.399

Google Scholar

[5] Tian Pau Chang. Performance study on the east–west oriented single-axis tracked panel. Energy 34 (2009) 1530–1538.

DOI: 10.1016/j.energy.2009.06.044

Google Scholar

[6] Xiudong Wei, Zhenwu Lu, Zhifeng Wang. A new method for the design of the heliostat field layout for solar tower power plantRenewable Energy, 35( 9), 2010, Pages 1970-1975.

DOI: 10.1016/j.renene.2010.01.026

Google Scholar

[7] B. Kelly.D. Kearney. Parabolic Trough Solar System Piping Model Final Report. Subcontract Report NREL/SR-550-40165. July 2006.

DOI: 10.2172/887341

Google Scholar

[8] S.D. Odeh et al.Performance evaluation of solar thermal electric generation systems,Energy Conversion and Management 44 (2003) 2425–2443.

DOI: 10.1016/s0196-8904(03)00011-6

Google Scholar

[9] Odeh SD, Behnia M, Morrison GL. Hydrodynamic analysis of direct steam generation solar collectors. Sol Energy Eng, ASME 2000;122:14–22.

DOI: 10.1115/1.556273

Google Scholar

[10] M.J. Montes, A. Abanades, J.M. Martnez-Val.Performance of a direct steam generation solar thermal power plant for electricity production as a function of the solar multiple. Solar Energy 83 (2009)679–689.

DOI: 10.1016/j.solener.2008.10.015

Google Scholar

[11] M.J. Montes, A. Abanades, J.M. Martnez-Val b, M. Valdes.Solar multiple optimization for a solar-only thermal power plant, using oil as heat transfer fluid in the parabolic trough collectors. Solar Energy 83 (2009) 2165–2176.

DOI: 10.1016/j.solener.2009.08.010

Google Scholar

[12] Qiu Guoquan, Xia Yanjun, Yang Hongyi. An optimized clear day solar radiation model. Acta Energiae Solaris Sinica. Vol22 (14),2001.456-460 (in Chinese)

Google Scholar

[13] J.A. Duffie W.A. Beckman. Solar engineering of thermal processes.1991,Wiley,New York.

Google Scholar

[14] William B. Stine and Michael Geyer. power from the sun[M]. http://www.powerfromthesun.net/book.htm

Google Scholar

[15] Angela M. Patnode.Simulation and performance Evaluation of Parabolic trough solar power plants:[master paper].Sanford A. Klein: University of Wisconsin-Madison,1996,98`~100

Google Scholar

[16] Thorsten A. Stuetzle.Automatic Control of the 30MWe SEGS VI Parabolic Trough Plant: [master paper].University of Wisconsin-Madison,2002,181~190.

Google Scholar