Development and Application of Continuous Atmospheric Heavy Metals Monitoring System Based on X-Ray Fluorescence

Article Preview

Abstract:

This paper presents a continuous atmospheric heavy metals monitoring system (AMMS-100) for heavy metals analysis based on X-ray fluorescence (XRF) technology. The AMMS-100 is used to collect the sample automatically with filters and then measure the concentrations of heavy metals by XRF. The accuracy of AMMS-100 for heavy metals analysis has been verified by the standard method. The relative errors, such as Pb and Fe, are lower than 10%. Moreover, the AMMS-100 can be used for long-term continuous monitoring the atmospheric heavy metals under different weather condition. The AMMS-100 described herein presents a continuous system for accurate analysis of atmospheric heavy metals with long-term stability.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 518-523)

Pages:

1510-1515

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] J. M. Pacyna, E. G. Pacyna and W. Aas in: Changes of emissions and atmospheric deposition of mercury, lead, and cadmium, edited by Atmospheric Environment, Vol. 43(2009), pp.117-127.

DOI: 10.1016/j.atmosenv.2008.09.066

Google Scholar

[2] Determination of Metals in Ambient Particulate Matter Using X-ray Fluorescence (XRF) Spectroscopy, Method IO-3.3, U.S. Environmental Protection Agency, June, 1999.

Google Scholar

[3] W. Shotyk, D. Weiss, J. D. Kramers, R. Frei, A. K. Cheburkin, M. Gloor and S. Reese in: Geochemistry of the peat bog at Etang de la Gruère, Jura Mountains, Switzerland, and its record of atmospheric Pb and lithogenic trace metals (Sc, Ti, Y, Zr, and REE) since 12,370 14C yr BP, edited by Geochimica et Cosmochimica Acta, Vol. 65(2001), pp.2337-2360.

DOI: 10.1016/s0016-7037(01)00586-5

Google Scholar

[4] T. A. Pakkanen, K. Loukkola, C. H. Korhonen, M. Aurela, T. Mäkelä, R. E. Hillamo, P. Aarnio, T. Koskentalo, A. Kousa and W. Maenhaut in: Sources and chemical composition of atmospheric fine and coarse particles in the Helsinki area, edited by Atmospheric Environment, Vol. 35(2001), pp.5381-5391.

DOI: 10.1016/s1352-2310(01)00307-7

Google Scholar

[5] Y. Gao, E. D. Nelson, M.P. Field, Q. Ding, H. Li, R. M. Sherrell, C. L. Gigliotti, D. A. Van Ry, T. R. Glenn and S. J. Eisenreich in: Characterization of atmospheric trace elements on PM2.5 particulate matter over the New York–New Jersey harbor estuary, edited by Atmospheric Environment, Vol. 36(2002), 1077-1086.

DOI: 10.1016/s1352-2310(01)00381-8

Google Scholar

[6] M. T. S. D. Vasconcelos and H. M. F. Tavares in: Atmospheric metal pollution (Cr, Cu, Fe, Mn, Ni, Pb and Zn) in Oporto city derived from results for low-volume aerosol samplers and for the moss Sphagnum auriculatum bioindicator, edited by The Science of the Total Environment, Vol. 212(1998), pp.11-20.

DOI: 10.1016/s0048-9697(97)00322-7

Google Scholar

[7] M. Yatin, S. Tuncel, N. K. Aras, I. Olmez, S. Aygun and G. Tuncel in: Atmospheric trace elements in Ankara, Turkey: 1. factors affecting chemical composition of fine particles, edited by Atmospheric Environment, Vol. 34(2000), pp.1305-1318.

DOI: 10.1016/s1352-2310(98)00297-0

Google Scholar

[8] L. Zhang, J. Chen and R. J. Jing in: Determination of 12 Elements in Lotus Seed Core by ICP-AES, edited by Chinese Journal of Spectroscopy Laboratory, 26(2009), pp.316-319.

Google Scholar

[9] K. Tsuji and K. Nakano in: X-ray Spectrometry, edited by Analytical Chemistry, Vol. 82(2010), pp.4950-4987.

Google Scholar

[10] Ambient air-Determination of lead-Graphite furnace atomic absorption spectrometry (Trial), HJ 539-2009, State Environmental Protection Administration of China, April, 2010.

Google Scholar

[11] Inductively Coupled Plasma-Mass Spectrometry, Method 6020A, U.S. Environmental Protection Agency, Revision 1, February, 2007.

Google Scholar