Effects of Operating Parameters and Loading Modes on the Dynamic Cell Performance of PEM Fuel Cells

Article Preview

Abstract:

This paper experimentally investigates the dynamic response of a single fuel cell under various dynamic loadings with different operating conditions. Three kinds of loadings are applied to the PEM fuel cell and they are simulated NEDC mode, simulated 10/15 mode, and modified mode. The operating conditions are set at different cell temperatures, humidification temperatures, and stoichiometric rates during each test to study the effects of these parameters on the cell performance of a PEM fuel cell. The cell performance is found increased with increasing cell temperature in the range of 45-65°C. On the other hand, there exist optimal conditions for the humidification temperature and the stoichiometric rate at 70°C/60°C and 1.5/2.0 on the anode and cathode sides, respectively.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 532-533)

Pages:

135-139

Citation:

Online since:

June 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Acres GJK., J Power Sources 2001; 100: 60-6.

Google Scholar

[2] Von Spakovsky MR, Olsommer B., Energy Convers Manage 2002; 43: 1249-57.

Google Scholar

[3] Xie J, Wood DL III, Wayne DM, Zawodzinski TA, Atanassov P, Borup RL., J Electrochem Soc 2005; 152: A104-13.

DOI: 10.1149/1.1830355

Google Scholar

[4] Helmolt R, Eberle U., J Power Sources 2007; 165: 833-43.

Google Scholar

[5] Costa RA, Camacho JR., J Power Sources 2006; 161: 1176-82.

Google Scholar

[6] Hamelin J, Agbossou K, Laperriere A, Laurenfuel celle F, Bose TK., Int J Hydrogen Energy 2001; 26: 625-9.

Google Scholar

[7] Kim S, Simpalee S, Van Zee JW., J Power Sources 2004; 135: 110-21.

Google Scholar

[8] Corbo P, Migliardini F, Veneri O., J Power Sources 2008; 181: 363-70.

Google Scholar

[9] Mitchell W, Bowers BJ, Garnier C, Boudjemaa F., J Power Sources 2006; 154: 489-96.

Google Scholar

[10] Yan Q, Toghiani H, Causey H., J Power Sources 2006; 161: 492-502.

Google Scholar

[11] Amphlett JC, Mann RF, Peppley BA, Roberge PR, Rodridgues A., Applied Thermal Engineering, 24, 501-513.

Google Scholar

[12] Yan WM, Soong CY, Chen F, Chu HS., J Power Sources 2005; 143: 48-56.

Google Scholar

[13] Yan WM, Chu HS, Chen JY, Soong CY, Chen F., J Power Sources 2006; 162: 1147-56. Fig. 1 Dynamic loading modes: (a) Mode 1: based on new European drive cycle mode (NEDC); (2) Mode 2: based on Japanese 10/15 mode; and (c) Mode 3: modified from Mode Fig. 2 Effects of (a) cell temperature and (b) humidification temperature on fuel cell dynamic response performance under loading mode 1. Fig. 3 The effects of dynamic loading modes on the galvanic response of a fuel cell with higher cell temperature Tcell=65oC. Fig. 4 The effects of dynamic loading modes on the galvanic response of a fuel cell with lower stoichiometric rate la/lc=1. 0/1. 0.

DOI: 10.1002/fuce.201100154

Google Scholar