Monodispersion Soot Position Interference Mechanism on Measuring the Soot Concentration Using the Scattering Method

Article Preview

Abstract:

The soot emission concentration of the stationary pollution sources is one of the important measurement parameters of the atmosphere pollution CEMS. The monodispersion soot position can affect the original measurement light intensity and reduce the soot concentration measurement accuracy. To reduce the monodispersion soot particles position interference, the monodispersion soot particles position interference mechanism is studied in this paper. The difference angle range scattering light intensity of the monodispersion soot is calculated. The numerical simulation results show that the difference soot position can reduce the soot concentration measurement accuracy. The solution method is brought out and can improve the measurement accuracy.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

285-288

Citation:

Online since:

June 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wallis, G. B. (1969). One-dimensional Two-phase Flow, Mc-Graw Hill, Inc., New York, NY, USA, pp.123-134.

Google Scholar

[2] Zhao Yanjun, et al. (2004). "The Study Of Light Scattering Average Value Method Online Monitoring Exhaust Dust Particle Concentration", Journal Of Electrical Engineering Of China, 11(24), pp.217-221

Google Scholar

[3] Yu Zhengran et al. (1990). "Dust Testing Practical Skills", China Environmental Science Press, Beijing, China

Google Scholar

[4] Mu Ning (2004). "Continuous Measurement of Soot Concentration in the Exhaust Duct, " Southeast University

Google Scholar

[5] Cai Xiaoshu, et al. (2001). "The Study of Diagonosing the Running Condition of Pulverized Coal in Pipe, " Proceedings of the CSEE 21(7), pp.83-86

Google Scholar

[6] Juliuse B.Gajewski, (1999). "Non-intrusive Solids Charge and Mass Flow Measurements with an electrostatic Flow Probe, " Journal of Electrostatics, 46, pp.317-330

DOI: 10.1016/s0304-3886(98)00064-3

Google Scholar

[7] Li Qiping,(2001). "The Current Situation and Problem of Continuous On-line Testing Technology for Stack Dust in China," Sensor World, pp.25-29

Google Scholar

[8] Su Mingxu, (2002). "The Ultrasonic Measurement Theory of the Particle Size Distribution and Concentration in the Gas-Solid Flow , " University of Shanghai Science and Technology

Google Scholar

[9] Ding Weiying,(2008). "Optical Monitoring System of the Soot Concentration in the Duct by the Scattering-Transmission method, " Hebei Polytechnic University

Google Scholar