Temperature Control and Crack Prevention of High-Performance Concrete Pier in San Yang Gang Tide Gate

Article Preview

Abstract:

San Yang Gang tidal sluice gate is easily to produce temperature crack at early age because of the use of pump hydrotechnic high performance concrete in the constructing process. Based on the analysis of parameters of three-dimensional temperature field and temperature stress field, comprehensive measures which are consist of lower inside temperature through cooling water pipes , keep the outer surface moist, increase temperature distribution bars, reduce pumping concrete slump and mixing polypropylene fiber were proposed. These comprehensive measures have solved the problem of temperature control and crack prevention successfully.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 573-574)

Pages:

1203-1210

Citation:

Online since:

October 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] San Yang Gang to block the tide gate on the floor and pier high-performance mass concrete temperature control measures research report, Hohai University, 2010. 12.

Google Scholar

[2] Xiongjie Zhou, Cao'e high-performance concrete pier early temperature and crack control [J]. China Water Transport, 2009 (4). 0142-03.

Google Scholar