p.2040
p.2045
p.2050
p.2054
p.2061
p.2065
p.2069
p.2074
p.2078
In Situ Detection of Thermal Cycle in Weld Metal of Cr-Mo Steel
Abstract:
With the self-designed system of welding thermal cycle test, low alloy steel of Cr-Mo series was welded through proper welding procedure according to the phenomenon of cold crack and local hardening in weld metal, and in-situ detection of thermal cycle for deposit metal was realized. The results show that self-designed system is reliable within the error range, the maximum peak temperature during thermal process was above 1700°C, it is largely improved than reported formerly.
Info:
Periodical:
Pages:
2061-2064
Citation:
Online since:
December 2012
Authors:
Keywords:
Price:
Сopyright:
© 2013 Trans Tech Publications Ltd. All Rights Reserved
Share:
Citation: