Simulation Analysis of Suppressing Lightning Overvoltage in Automatic Weather Station Collector by Ferrite

Article Preview

Abstract:

With the advancement of meteorology modernization, automatic weather station had become an important means of atmospheric sounding. Collecting data and information security were basic requirements for meteorological monitoring and forecasting. When lightning struck large scale and very large scale integrated circuits, the automatic station can be damaged or its data collector can be interrupted. Two-level SPD lightning protection system and three-level ferrite lightning protection system can compensate for the lack of lightning protection board and power protector. MATLAB simulation analysis shows that the three level lightning protection circuits with ferrite are better than the two level SPD circuits in guaranteeing the automatic station operation. Putting the ferrite rings around the power lines or communication lines, along with the common lightning protection devices, can make the load terminal voltage limit to 500V. The lightning current is significantly reduced by using the simple method in the collector.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 610-613)

Pages:

341-346

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yin Yuexin, Wu Alex Y,Blackburn Tom. Investigation of electric drives system responses to lightning related voltage sags[C].IEEE Conference Record of Annual Pulp and Paper Industry Technical Conference.Sea,WA,USA:IEEE,1999:83-89.

DOI: 10.1109/papcon.1999.779349

Google Scholar

[2] Boonseng C, Kinnares V. Analysis of harmonic for 12-pulse converter under unbalanced voltage operation due to lightning related voltage sags and short interruption [C].Proceedings of the IEEE Power Engineering Society Transmission and Distribution Conference. Columbus, OH,USA: IEEE, 2001: 1009- 1014.

DOI: 10.1109/pesw.2001.917206

Google Scholar

[3] Xianggen Gan, Lijun Jin , Lihong Chen,. Lightning impulse overvoltage protection for automatic meteorological station[J].High Voltage Apparatus, 2004, 40(5):35-354.

Google Scholar

[4] Xianggen Gan, Lijun Jin , Lihong Chen, Runsheng Luo, etal. Suppressing Lightning Overvoltage in Automatic Meteorological Station by Ferrite[J]. High Voltage Engineering, 2007, 33(5):18-21.

Google Scholar

[5] GB50343-2004 Technological specifications of lightning protection for electronic information system of building[S]. Beijing:China Architecture and Building Press, 2004.

Google Scholar

[6] Xianggen Gan, Lijun Jin , Lihong Chen, etal. Characteristic parameter analysis of the suppressing VFTO in GIS by ferrite[J]. High Voltage Engineering, 2004, 30(9):24- 26.

Google Scholar

[7] Yufeng Hu . Principle and measure of automatic meteorological station[M].Beijing: China Meteorological Press,2004.

Google Scholar

[8] Klaus Beiyi Telectronic Components[M]. Beijing: Science Press,1999.

Google Scholar