Thermal Calculation on SAGD Steam Delivery System

Article Preview

Abstract:

A flowing and heat transfer model of superheated steam has been established. Thermal calculation of high-quality wet steam injectors of Du84-54-160 and Du84-60-58 in Block Shu-1 and data analysis of part of the pipelines of SAGD-2# steam injection station have been completed with this model. The results and the actual data match very well with each other.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

162-165

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhang Rui. Heavy Oil Thermal Recovery Technology, Petroleum Industry Press, the first edition, Apr. 1999, Beijing.Reference to a book; In Chinese

Google Scholar

[2] Yang Liqiang, Lin Riyi.Research of Superheated Steam Injection Technique During SAGD. Oil and Gas Geology and Recovery, 2007, (5). In Chinese

Google Scholar

[3] Guo Erpeng. Production Prediction of SAGD in Pairs of Vertical Well and Horizontal Well. Fault Block Oil and Gas Field. May of 2008. In Chinese

Google Scholar

[4] GB50264-97 Industrial Equipment and Pipeline Insulation Engineering Design Specification, GB.1997. In Chinese

Google Scholar

[5] Chen Jialang. Two Phase Pipe Flow of Petroleum Gas and Liquid(M). Beijing: Petroleum Industry Press, Jan. 1989. In Chinese

Google Scholar

[6] Tong Jingshan, Li Jing. Calculation of Fluid Thermophysical Property. Beijing: Tsinghua University Press, 1982. Reference to a book:In Chinese

Google Scholar