A Fault Line Detection Method Based on Wavelet Packet Analysis in Distribution Network

Article Preview

Abstract:

With the rapid development of power network automation, the detection of the default single-phase grounding fault line in small current neutral grounding system has became a hot spot in research of power network system. Generally, power network neutral point is not grounded or grounded through arc-suppression coil grounding. When single phase grounding fault occurs, the power network system is named as small current grounding system since the grounding short-circuit is small due to a low-impedance short circuit.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

1833-1840

Citation:

Online since:

December 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Gong Jing, Study of wavelet selection for single-phase earth fault line selection in distribution network, Power System Protection And Control, 2009,37(18), pp.5-9.

Google Scholar

[2] Guo Qingtao, Wu Tian, Survey of the methods to select fault line in neutral point ineffectively grounded power system, Power System Protection And Control, 2010, 38(2), pp.146-152.

Google Scholar

[3] PAN Lu, Lv Yanping, YU Fang, et a1. Fault Line Selection in Non Solidly Earthed Network Based on Phase-frequency Characteristic and Multi-frequency Band Analysis[J]. Automation of Electric Power Systems, 2007, 3l( 4), pp.76-79.

Google Scholar

[4] WANG Yu-mei, DONG Yang-yang, LIE Xing-yan: Study on higher order wavelet packet singular entropy and its application to faulty line selection, Power System Protection And Control, 2011, 39(8) , pp.23-27.

Google Scholar

[5] PANG Qing—le, SUN Tong-jing, ZHONG Mai-ying. New Criterion of Faulty Line Detection for Distribution Networks Based on Wavelet Packet Analysis[J]. Power System Technology, 2006, Vol. 30, pp.394-397.

Google Scholar

[6] CHEN Zhi 1iang, FAN Chun.iu.Fault Line Selection for Small Current Neutral Grounding System based on the Fifm Harmonic Current Mutation in Distribution System[J]. Proceedings ofthe CSU-EPSA, 2006, 18(5), pp.37-41.

Google Scholar

[7] XUE Yong. Duan, FENG Zu-ten, XU Bing-yin. Et a1. Earth Fault Protection in Non. solidly Earthed Network Based on Transient Zero Sequence Current Comparison[J]. Automation of Electric Power Systems. 2003, 27(9), pp.48-53.

DOI: 10.1109/pesmg.2013.6672456

Google Scholar

[8] XING Y"hui, Ln Yan. Ping, ZHANG Cheng—xue. et a1. Study on all Equipment to Select Faulty Line in a Non-solid Earthed Network based on Polarity of Transient Current[J]. Engineering Journal of Wuhan University. 2005, 39(5), pp.105-109.

Google Scholar

[9] SU Zhan Tao, Ln Yah, Ping, A New Welet Packet Analysis Based Method to Detect Faulty Line for Single Phase to Ground Fault 0ccurred in Distribution Network with Small Current Neutral Grounding[J]. Power System Technology, 2004, 28(12), pp.30-33.

Google Scholar

[10] Yao Nan, HUO Bai, 1in, WANG Hui, et a1. A New Criterion for Earth Fault Line Selection based on Pelet Packets in Small Current Neutral Grounding System[J]. Proceedings ofthe CSEE. 2004, 24(6), pp.54-58.

Google Scholar