Research on Glucose Oxidase Biosensor Based on Reverse Iontophoresis

Article Preview

Abstract:

Objective: Making a glucose sensor to detect the glucose which is extracted from the tissue fluid on reverse iontophoresis. Method: In the role of the catalysis of glucose oxidase which was fixed in polyethylene oxide gel, the glucose and potassium ferricyanide were change into gluconic acid and potassium ferrocyanide. Then we could get the concentration of glucose by detecting the current which was created by the redox reaction. Results: The glucose sensors could detect the concentration of glucose in the range of 2.2~22mmol/l and have a good linear too. The conformance test results show that the deviation of multiple measurements of the same sensor is less than 2% and the reaction time is less than 1s. Conclusion: The sensors could detect the blood glucose.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 641-642)

Pages:

785-788

Citation:

Online since:

January 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wild S, Rogilic G, Green A, et al. Global prevalence of diabetes: estimates for the year 2000 and projections for 2030, J. Diabetes Care. 27(2004)1047-1053.

DOI: 10.2337/diacare.27.10.2569-a

Google Scholar

[2] Q. H. Dai, Z. D. Wang. Present situation investigation of diabetes in China, J. Chinese medicine guidelines. 13(2011)206-207.

Google Scholar

[3] Y.L. Liu, S.X. Zhang, W. L. Liu et al. The progress of blood glucose detection method, J. Spectrum instrument and analysis. 2(2003)4-9.

Google Scholar

[4] Kurnik R, Oliver J, Waterhouse S, et al. Application of the Mixtures of Experts algorithm for signal processing in a noninvasive glucose monitoring system, J. Sensor Actuat B-Chem. 60(1999)19-26.

DOI: 10.1016/s0925-4005(99)00239-7

Google Scholar

[5] Kim D W, Kim H S, Lee D H, Kim H C. Importance of Skin Resistance in the Reverse Iontophoresis based Noninvasive Glucose Monitoring System, C. Proceedings of the 26th Annual International Conference of the IEEE EMBS San Francisco, CA, USA, September 125(2004).

DOI: 10.1109/iembs.2004.1403704

Google Scholar

[6] POTTS R, TAMADAJ, TIERNEYM. Glucose monitoring by reverse iontophoresis, J. Diabetes Metabolism Research and Reviews. 18(2002)4953-4955.

Google Scholar

[7] Yangyang Liu, Hong Wang. Research Progress on Non-Invasive Glucose Monitoring Based on Reverse Iontophoresis, C. Advanced Materials Research. 529(2012)361-365.

DOI: 10.4028/www.scientific.net/amr.529.361

Google Scholar