Phenomenon of Radiation Asymmetry in The Capillary Plane Air-Conditioning Systems

Article Preview

Abstract:

Based on the introduction characteristics of capillary plane radiation air conditioning systems, we focuse on the analysis phenomenon of radiation asymmetry in the radiant air conditioning systems in the engineering practice , and discuss the condition that produces this phenomenon, and establish mathematical model of radiation asymmetric in the capillary plane air conditioning systems. And we work out the radiation angle coefficient between the human body and the floor, south wall, north wall, east wall , west wall in air conditioning rooms, and expound the radiation asymmetry degree in different parts of air conditioning rooms. The result is of positive significance to research capillary plane radiation air conditioning systems deeply and to improve occupant comfort .

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 671-674)

Pages:

2555-2558

Citation:

Online since:

March 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yi Jiang. Temperature and Humidity Independent Control Air Conditioning System [M]. Beijing: China Building Industry Press, (2005).

Google Scholar

[2] YangCheng Shih, ChengChi Chiu, Oscar Wang. Dynamic airflow simulation with in an isolation room. Building and Environment. 2007, 42: 3194–3209.

DOI: 10.1016/j.buildenv.2006.08.008

Google Scholar

[3] Xiaoxiong Yuan, Qingyan Chen, Leon R Glicksman, etc. Measurements and Computations of Room Airflow with Displacement Ventilation. ASHRAE Transactions. 1999(105): 340-352.

Google Scholar

[4] Qingyan Chen, Leon Glicksman. System performance evaluation and design Guidelines for displacement ventilation[M] . ASHRAE Inc, 2003: 1-6.

Google Scholar

[5] Jeong, J.W. and S.A. Mumma. Practical thermal performance correlations for molecular sieve and silica gel loaded enthalpy wheels., Applied Thermal Engineering, 2005(25): 719–740.

DOI: 10.1016/j.applthermaleng.2004.07.018

Google Scholar

[6] Steven J. Emmerich, Tim McDowell. Initial Evaluation of Displacement Ventilation and Dedicated Outdoor Air Systems for U.S. Commercial Buildings. 2005(101)438-442.

DOI: 10.6028/nist.ir.7244

Google Scholar

[7] Steven J. Emmerich, Tim McDowell. Initial Evaluation of DV and DOAS for U.S. Commercial Buildings. NIST. 2005(45)191-195.

Google Scholar

[8] Xiaoxiong Yuan, Qingyan Chen, Leon R Glicksman. A Critical Review Of Displacement Ventilation. ASHRAE Transactions; 1998(104): 78-90.

Google Scholar