Simplified Calculation Methods about Bottom Surface Size of Shallow Foundation Bearing Eccentric Load

Article Preview

Abstract:

Direct calculating method was deduced from the requirements of pressure on foundation bottom surface to avoid loop computing and verified by an example. Worksheet of Excel was created and calculating via Goal Seek of Excel was presented, the initial width value of foundation should not less than 0.12m. The direct calculating method is very simple, convenient and rapidly. Calculating via Goal Seek of Excel is intuitive but you need to know how to use Excel. It is more simple if create another worksheet of Excel via the direct calculating method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

658-661

Citation:

Online since:

June 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] GB50007-2011. Code for design of build foundation. China Architecture and Building Press. Beijing. 2011. (In Chinese).

Google Scholar

[2] Information on http://www.dummies.com/how-to/content/how-to-use-excel-2010s-goal-seek-feature.html