Reconstruct the PWM Signal of Switching Power Supplies from the Near Field Radiation

Article Preview

Abstract:

A non-contact testing method is proposed for encapsulation treated or insulation coated switching power supplies, which is implemented by reconstructing the pulse width modulation (PWM) signal of switching converters from the near field radiation of magnetic components. The radiation pattern of a buck converter is investigated, and the magnetic field sensing probe and PWM signal reconstruction circuit are also illustrated. The reconstruction testing is carried out on a buck converter; the duty cycle error of the reconstructed PWM signal is less than 0.2%, which validates the proposed method.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 718-720)

Pages:

1792-1796

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Smith D.C., Signal and noise measurement techniques using magnetic field probes, Electromagnetic Compatibility 1999 IEEE International Symposium on, vol.1, pp.559-563,1999.

DOI: 10.1109/isemc.1999.812967

Google Scholar

[2] Vives-Gilabert Y., Arcambal C., Louis A., de Daran F., Eudeline P., Mazari B., Modeling magnetic radiations of electronic circuits using near-field scanning method, Electromagnetic Compatibility IEEE Transactions on, vol.49, no.2, pp.391-400, May 2007.

DOI: 10.1109/temc.2006.890168

Google Scholar

[3] Hernando M.M., Fernandez A., Arias M., Rodriguez M., Alvarez Yu., Las-Hera F., EMI radiated noise measurement system using the source reconstruction technique, Industrial Electronics IEEE Transactions on, vol.55, no.9, pp.3258-3265, Sept 2008.

DOI: 10.1109/tie.2008.928042

Google Scholar

[4] Slattery K.P., Muccioli J.P., North T.M., Constructing the Lagrangian of VLSI devices from near field measurements of the electric and magnetic fields, Electromagnetic Compatibility 2000. IEEE International Symposium on, vol.1, pp.129-134 vol.1, 2000.

DOI: 10.1109/isemc.2000.875550

Google Scholar

[5] Aouine O., Labarre C., Costa F., Measurement and modeling of the magnetic near field radiated by a buck chopper, Electromagnetic Compatibility IEEE Transactions on, vol.50, no.2, pp.445-449, May 2008.

DOI: 10.1109/temc.2008.922794

Google Scholar

[6] Yu Chen, Xuejun Pei, Songsong Nie, Yong Kang, Monitoring and diagnosis for the DC–DC converter using the magnetic near field waveform, Industrial Electronics IEEE Transactions on, vol.58, no.5, pp.1634-1647, May 2011.

DOI: 10.1109/tie.2010.2051939

Google Scholar

[7] Aime J., Roudet J., Clavel E., Aouine O., Labarre C., Costa F., Ecrabey J., Prediction and measurement of the magnetic near field of a static converter, Industrial Electronics 2007 IEEE International Symposium on, pp.2550-2555, June 2007.

DOI: 10.1109/isie.2007.4375009

Google Scholar

[8] Guerin F., Labarre C., Lefebvre D., Magnetic near-field measurement for FDI of ZVS full bridge isolated buck converter, Diagnostics for Electric Machines, Power Electronics & Drives (SDEMPED) 2011 IEEE International Symposium on, pp.344-349, Sept 2011.

DOI: 10.1109/demped.2011.6063646

Google Scholar