Measurement and Analysis of the Power Frequency Electric Field under 500kV Transmission Lines

Article Preview

Abstract:

The power frequency electric field of the extra high voltage network, as an index which has an important effect on the ecological environment around has been valued by the power design and operate department. Studying the factors that affect electromagnetic environment of transmission line and protective measures can provide technical basis for the design of the transmission line, and make people to recognize the electromagnetic environment of transmission lines correctly and select the rational protection measures. In this paper, firstly the physical model of overhead transmission lines was built and the electric field was calculated, then the actual electric field under 500 kV transmission line in Jiaozuo was measured using the electromagnetic analyzer PMM8053B, finally the correctness of the theory and model was verified using the MATLAB simulation software.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

131-134

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] LU Jingde, LIU Kai, ZHOU Teng. The research on the level of field strength and the protection when being maintenance operations of the 500 kV four circuits on the same tower. East China Electric Power. Vol. 38(2010), pp.108-112.

Google Scholar

[2] FU Chaoguo, SUN Yanzhou. Measurement, Calculation and Analysis of Ground Electric Field of Super High-voltage Transmission Line. Industry and Mine Automation.Vol.52(2011),pp.52-54.

Google Scholar

[3] CHEN Xiaobin, LI Yuefang. Analysis of electromagnet-tic radiation and its protection measures. Popular science.Vol. 94(2006), pp.175-179.

Google Scholar

[4] QIAN Yonglin, BIAN Rong. Analysis of  transmission line impact on the urban environment. Construction of the electric power.Vol.26(2005), pp.60-62.

Google Scholar

[5] SHAO Junnan, LI Tie. The analysis of the phase arrangement of the two circuits on the same tower impact on the electric fields. Xinjiang Electric Power Technology. Vol.104(2010),pp.81-82.

Google Scholar

[6] CIGRE Working Group on Article 36.01.Electric and magnetic fields generated power by transmission system. Beijin: China Electric Power Press,1984.

Google Scholar

[7] JIANG Hong, JIAO Jinghui, LIN Zhihe. Research on the measurement of electric fields overrun of the EHV transmission line. High voltage engineering. Vol. 32(2006), pp.61-63.

Google Scholar

[8] QIANG Shengze. Theoretical calculations of the electric fields below the transmission line 220kV two circuits on the same tower. High voltage engineering. Vol. 30 (2004), pp.45-46.

Google Scholar