Abstract:

The performance of biochemical treatment effluent from paper making wastewater treated by Fenton process was evaluated. The experiment result shows that the importance of influencing factors for Fenton oxidation treatment was H2O2 concentrations > pH > FeSO4 concentrations > reaction time. With the optimal conditions of reaction, that is pH3 (initial pH5), FeSO4 3.6 mmol/L, H2O2 3.4 mmol/L, and reaction time 60 min, the removals of COD and color for papermaking wastewater reached over 85% and 90%, respectively. The result also showed that in the process of Fenton method in the treatment of papermaking wastewater, for removing COD, the function by oxidation account for 15.5%, and the function of flocculation accounted for 69.8%.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 726-731)

Pages:

1760-1763

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] W.X. Liu, F.S. Zhang: Fundamental of Chemical Engineering, vol. 233-235(2011), p.132

Google Scholar

[2] O.Riessner: Wochenblatt Fur Papierfabrikation, vol.138(2010), p.546

Google Scholar

[3] D.Dutt, C.H. Tyagi: Indian Journal of Chemical Technology, vol.18(2011), p.145

Google Scholar

[4] M.H.Li, X.K. Meng: Advanced Research on Information Science, Automation and Material System, vol. 219-220(2011): p.370

Google Scholar

[5] M.Z. Huang: Industrial & Engineering Chemistry Research, 2012. vol.51(2012), p.6166.

Google Scholar

[6] F.L. Su: 2011 3rd International Conference on Environmental Science and Information Application Technology Esiat, Vol 10, (2011), p. (1961)

Google Scholar