Study on Disposing Landscape Water with Polyaluminum Ferric Chloride Composite Flocculants

Article Preview

Abstract:

The flocculation effect of poly aluminum ferric chloride (PAFC), diatomit and poly(dimethyldiallyl ammonium chloride) (HCA) which was used alone or cooperated with each other, on the water treatment of the urban landscape waters in Cangzhou was studied. The effect factors included the dosage and proportion of flocculent, the pH and sedimentation time. The experiment results showed that the effect of PAFC cooperating with diatomit or HCA was better than that of the single one. The optimum mass concentration ratio of PAFC to diatomit was 1: 4, a lower mass concentration benefited the removal of turbidity. The turbidity removal effect of PAFC+HCA is the best, with the optimum mass concentration of PAFC 35mg/L, HCA 0.5mg/L ,the best pH=8~9 and the sedimentation time of 1.5 hour, the removal ratio of turbidity was as high as 94%.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 726-731)

Pages:

2305-2309

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ping Zou, Shuangying Jiang, Tingyao Gao. China Water & Wastewater, 2003,19(2):2-3(In Chinese)

Google Scholar

[2] Dong Jing, Jun Liu, Danping Xie, et al. Environmental Science and Environmental Science and Management , 2008,33(12): 95-97(In Chinese)

Google Scholar

[3] Ghernaout B, Ghernaout D, Saiba A. Desalin Water Treat, 2010, 20(1/2/3): 133-143.

Google Scholar

[4] Guanghong Zheng, Bangtian Xia, Junlian Qiao, et al. China Water & Wastewater, 2008, 24(11): 72-75(In Chinese)

Google Scholar

[5] Xiuyuan Liao, Hongjuan Wu. Guangdong Chemical Industry, 2009, 36( 9): 103-106(In Chinese)

Google Scholar

[6] Xinjie Li, Wenfei Zhu, Yuejun Zhang, et al. China Rural Water and Hydropower, 2007, (12): 64-66(In Chinese)

Google Scholar

[7] Chen Jiang,Ren Wang,Wei Ma. Colloid Surf A: Physicochem Eng Asp, 2010, 369(1/2/3): 260-267.

Google Scholar

[8] Lijuan Liu, Lin Wang, Mingyu Li , et al. China Water & Wastewater, 2010, 26(5): 80-83(In Chinese)

Google Scholar

[9] Minghe He, Chunde Wu, Wei Jin, et al. Industrial Water Treatment, 2005, 25(5) : 25-30(In Chinese)

Google Scholar

[10] Xiaojie Xu, Chunde Wu, Qi Dong, et al. Chinese Journal of Environmental Engineering, 2011, 5(9) : 1979-1983(In Chinese)

Google Scholar

[11] Qinyan Yue, Huazhang Zhao, Baoyu Gao. Industrial Water Treatment, 2002, 22(3): 26-31(In Chinese)

Google Scholar

[12] Guirong Wang, Jie Zhang. Industrial Water & Wastewater, 2005, 36(5) : 27-29(In Chinese)

Google Scholar

[13] Xiaojie Xu. Enhanced Coagulation for Treating Slightly Polluted Algae-containing Surface Water Combining Polyaluminium Chloride (PAC) with Diatomite [D]. Guang Zhou: South China University of Technology, 2011. (In Chinese)

DOI: 10.1016/j.desal.2011.06.007

Google Scholar

[14] Chunlei Gu, Yifeng Yu, Guangyu Wang. Industrial Water Treatment, 2007, 27(9): 48-50(In Chinese)

Google Scholar

[15] Hongyi Lin. Technology & Development of Chemical Industry, 2010, 39(8) : 59-63(In Chinese)

Google Scholar

[16] Lifeng Chen, Mingjun Li, Shigui Wan, et al. Journal of Nan Chang Institute of Aeronautical Technology, 1995, (2): 33-39(In Chinese)

Google Scholar