Integration of Multiple in-House Heat Stations into One Energy Flexible Heat System - Part 2

Article Preview

Abstract:

Integration of several in-house heat stations containing of multiple boilers of different capacity and energy carriers can be economical profitable. This study contains further analyze and development of previous work by Riise and Sørensen [1-3]. Boiler start-up costs effect of the overall energy cost has been investigated and found to have an impact of boiler configurations in a system based on lowest specific running energy cost. A study of operational hours of boilers indicates if boilers can be dismounted form the integrated system. It is also performed simulations for lowest energy consumption instead lowest energy cost. Finally a heat pump model is introduced and analyzed. Introduction of the heat pump reduces the total energy cost even if the heat sink is increased with a fourth building.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 732-733)

Pages:

513-526

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] R. Riise and B. R. Sørensen: The influence of oversized boilers on power efficiency, energy consumption and cost in energy flexible heat stations. Part 1. Applied Mechanics and Materials, Vols. 291-294 (2013) pp.1816-1825, Switzerland (2013).

DOI: 10.4028/www.scientific.net/amm.291-294.1816

Google Scholar

[2] R. Riise and B. R. Sørensen: The influence of oversized boilers on power efficiency, energy consumption and cost in energy flexible heat stations. Part 2. Applied Mechanics and Materials, Vols. 291-294 (2013) pp.1826-1833, Switzerland (2013).

DOI: 10.4028/www.scientific.net/amm.291-294.1826

Google Scholar

[3] R. Riise and B. R. Sørensen: Integration of multiple in-house heat stations into one energy flexible heat system. Applied Mechanics and Materials, Vols. 291-294 (2013) pp.1777-1178, Switzerland (2013).

DOI: 10.4028/www.scientific.net/amm.291-294.1777

Google Scholar

[4] C. Kraguerud et al.: Analyse vedrørende intermittent drift av elektro- og oljekjeler, avhengig av kjeltype og anvendt brensel. Offprint Meddelelser nr. 2/1984. Kjelforeningen, Norway (1984) (In Norwegian.)

Google Scholar

[5] J.R. Nielsen. A model of optimization and analysis for energy flexible boiler plants for building heating purposes. PhD dissertation. The Norwegian institute of technology, Norway (1996).

Google Scholar

[6] J. Ø. Nilsen: A computer model for planning of energy systems with time dependent components and boundary conditions. PhD dissertation. The Norwegian institute of technology, Norway (1994)

Google Scholar

[7] K. Krüger, R. Franke and M. Rode. Optimization of boiler start-up using a nonlinear boiler model and hard constraints. Energy, 29, (2004).

DOI: 10.1016/j.energy.2004.03.022

Google Scholar

[8] J. Stene. Varmepumper - bygningsoppvarming. NTH-SINTEF Kuldeteknikk, Norway (1991). (In Norwegian.)

Google Scholar

[9] S. S. Bertsch, E. A. Groll. Two stage air-source heat pump for residential heating and cooling applications in northern U.S. climates. International journal of refrigeration 31, pp.1282-1292 (2008).

DOI: 10.1016/j.ijrefrig.2008.01.006

Google Scholar

[10] Y. Tong et al. Greenhouse heating using heat pumps with high coefficient of performance (COP). Biosystems engineering 106, pp.405-4011 (2010).

DOI: 10.1016/j.biosystemseng.2010.05.003

Google Scholar

[11] I. S. Ertesvåg. Uncertainties in heat-pump coefficient of performance (COP) and exergy efficiency based on standardized testing. Energy and buildings 43, pp.1937-1946 (2011).

DOI: 10.1016/j.enbuild.2011.03.039

Google Scholar

[12] C. Verhelst et al. Study of the optimal control problem formulation for modulating air-to-water heat pumps connected to residential floor heating system. Energy and building 45, pp.43-53 (2012).

DOI: 10.1016/j.enbuild.2011.10.015

Google Scholar

[13] Norwegian meteorological institute. http://www.eklima.no. Accessed April 2012.

Google Scholar

[14] Nord Pool Spot ASA. http://www.nordpoolspot.com/Market-data1/Downloads/Historical- Data-Download1/Data-Download-Page/. Accessed April (2012)

Google Scholar

[15] NVE (2012) Norwegian Water Resources and Energy Directorate. http://www.nve.no/no/ Kraftmarked/Nettleie/Nettleiestatistikk/Nettleiestatistikk-naringskunder---2005-og-senere/. Accessed April 2012.

Google Scholar

[16] SSB (Statistic Norway). http://www.ssb.no/petroleumsalg/tab-2012-04-23-02.html. Accessed April 2012.

Google Scholar

[17] Felleskjøpet. http://produkter.felleskjopet.no/trade/productlist/859/. Accessed October 2012.

Google Scholar