Research Progress of Liquid Desiccant Evaporative Cooling Air Conditioning System

Article Preview

Abstract:

Evaporative cooling technology is a refrigeration technology by water evaporating endothermic, with zero-pollution, environmental-friendly, energy saving, and other advantages, which makes it widely used. Nevertheless, due to its working characteristic, the application of evaporative cooling technology is limited, particularly in some areas with high humidity. Using the liquid desiccant dehumidification and evaporative cooling technology leads to a solution, named liquid desiccant evaporative cooling air conditioning system extends the application of evaporative cooling technology. This article on liquid desiccant evaporative cooling system provides a brief overview about research status, full usage of the low grade thermal energy, the practical application and new development of the system.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 732-733)

Pages:

531-536

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Guangli Zhang, Jin Wang, Jianhua Liu, et al, Performance analysis of a kind of air conditioning system using liquid desiccant. Refrigeration and Air-Conditioning.2004,4(6):60-62 (In Chinese)

Google Scholar

[2] Xiaosong Zhang, Xiufeng Fei, Mingheng Shi, et al, Study on the dehumidifier of energy storage liquid desiccant cooling systems. Journal of Southeast University (Natural Science Edition). 2003,33(1)(In Chinese)

Google Scholar

[3] Rongquan Cao, Xiaosong Zhang, Donggen Peng, Liquid desiccant evaporative cooling air-conditioning systems and certain key problems.HV&AC.2009,39(9):13-19(In Chinese)

Google Scholar

[4] Scalabrin G, Scaltriti G A., Liquid sorption-desorption system for air conditioning with heat at lower temperature. Journal of Solar Energy Engineering.(1990)

DOI: 10.1115/1.2929649

Google Scholar

[5] Wilkinson W H., Evaporative cooling trade-offs in liquid desiccant. ASHRAE Transactions.(1991)

Google Scholar

[6] Gang Li, Optimization design of desiccant evaporative cooling air-conditioning. Refrigeration and Air-Conditioning.2008,8(5):82-85(In Chinese)

Google Scholar

[7] Xiaolong Gong, Jian Sun, Mingheng Shi, et al, Contrast experimental study on performance of desiccation of desiccants solution. Refrigeration and Air-Conditioning.2005,5(5):81-84(In Chinese)

Google Scholar

[8] Sheng Yang, Lei Luo, Xin Wei, Research on the system of solution dehumidification technology and evaporation cooling air-conditioning.Technique Front .2009,38-40(In Chinese)

Google Scholar

[9] Hellmann H M, Grossman G., Simulation and analysis of an open-cycle dehumidifier-evaporator-regenerator (DER) absorption chiller for low-grade heat utilization. International Journal of Refrigeration .1995,18(3)

DOI: 10.1016/0140-7007(95)90314-p

Google Scholar

[10] Lof G O G., Cooling with solar energy.1995 Congress on solar Energy.1995:171-189

Google Scholar

[11] Xiaosong Zhang, Xiufeng Fei, Primary research on dehydration and evaporative cooling system with energy storage using solution. Journal of Dalian University of Technology. 2001,41 (S1): 30-33(In Chinese)

Google Scholar

[12] Xiaosong Zhang, Yonggao Yin, Yiran Cao, Experimental study on the performance of liquid desiccant cooling air conditioning with energy storage. Journal of Engineering Thermophysics.2004,25(4):546-549(In Chinese)

Google Scholar

[13] Jun Lu, Yuxi Liu, Ling Xie, Xinhui Zhang. Patent CN202040912U. (2011)

Google Scholar

[14] Jun Lu, Yuxi Liu, Application of complex Liquid desiccant evaporative cooling air-conditioning system. GAS&HEAT.2012,32(4):26-30(In Chinese)

Google Scholar

[15] Zhong Liu, Evaporative Refrigeration Air Conditioning in Dry and Hot Regions. Building Energy & Environment. 2011,30(1):100-101(In Chinese)

Google Scholar

[16] Yongmei Xuan, Fu Xiao, Analysis on energy efficiency of a hybrid liquid desiccant and evaporative cooling system in Hong Kong. Building Science.2009,25(2)(In Chinese)

Google Scholar

[17] Zhiyi Wang, Ziwu Dai, Dongbo Wu, Research of evaporative cooling liquid solar desiccant air conditioning system design.International Refrigeration Technology communication.2010(In Chinese)

Google Scholar

[18] Jingde Zhao, Hailin Zhu, Yasu Zhou, Application of liquid desiccant in textile air condition //Proceeding of the 2009 Annual Conference of the Chinese Association of Refrigeration. 2009(In Chinese)

Google Scholar

[19] Yugang Wang, Jiaping Liu, Xiang Huang, et al, Energy saving potential of liquid desiccant evaporative cooling system in Xiamen. Fluid Machinery.2012,40(5):67-70(In Chinese)

Google Scholar

[20] Xiang Huang, Xiaowen Liu, Zhixiang Wu, et al, Experiments on dew-point indirect-direct evaporative cooling air conditioning unit.HV&AC.2011,41(5):104-108(In Chinese)

Google Scholar

[21] Qiang Zhang, Yutao Hao, Shuang Yang, et al, Research progress and present situation analysis of dew point indirect evaporative cooling technology. Refrigeration and Air-Conditioning.2010,10(1):17-22(In Chinese)

Google Scholar

[22] B. Riangvilaikul, S. Kumar. An experimental study of a novel dew point evaporative cooling system. Energy and Buildings.2010, 42(5):637-644

DOI: 10.1016/j.enbuild.2009.10.034

Google Scholar

[23] B. Riangvilaikul, S. Kumar. Numerical study of a novel dew point evaporative cooling system. Energy and Buildings.2010, 42(11):2241-2250

DOI: 10.1016/j.enbuild.2010.07.020

Google Scholar

[24] Shuang Yang, Zhongbao Liu, Qiang Zhang, et al, Study on the air conditioning system combining of solar liquid desiccant system and dew point indirect evaporative cooling//Proceeding of the ninth Refrigeration and Air Conditioning Technology Exchange Across the Taiwan Strait. 2009:20-24(In Chinese)

DOI: 10.4028/www.scientific.net/amr.516-517.1250

Google Scholar