Static Test and Bond Stress Analysis of the New Kind of Anchor for CFRP Tendon

Article Preview

Abstract:

A new kind of anchoring option is researched. The results show that the optimal scheme is feasible and effective. The main steps and programs of the static tension test are introduced. The testing and calculation methods of bond stress are introduced. Based on the actual engineering data, the research of bond stress under design tensile is proposed. A simplified model of the bond stress is established according to the experimental data. The results of checking show that bond stress distribution curve and the simplified model agree with the experiment. Maximum error is less than 7.2% and 7.0% respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

198-203

Citation:

Online since:

September 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Pan Zeng, Zhuo Sun. FRP applications in bridge construction [J]. Journal of Guangzhou University (Natural Science Edition), 2006, 5(2): 90-93.

Google Scholar

[2] Zhi Fang, Dong Ling. A Research Into Bond-type Anchorage of CFRP Tendon [J]. Journal of Central-south Institute of Technology, 2004, 18(1): 47-51.

Google Scholar

[3] Nanni A.,C.E. Bakis. Short-term sustained loading of FRP tendonanchor systems [J]. Construction and Building Materials, 1996, Vol. 10 (4), pp.255-266.

DOI: 10.1016/0950-0618(95)00097-6

Google Scholar

[4] Do Young Moon, Brahim Benmokrane. An exploratory study of GFRP rebar with ribs containing milled glass fibers [J]. Composites part B: Engineering. 2008, 39 (5): 882-890.

DOI: 10.1016/j.compositesb.2007.09.004

Google Scholar

[5] Jiawu Miao, Minshan Pei. Global Static Analysis of the Su-Tong Cable-Stayed Bridge [J]. Journal of Highway and Transportation Research and Development, 2006, 23(2): 64-67.

Google Scholar

[6] Qingcheng Meng, Xin Qi. Algorithm for Relevant Parameters of Stay Cables of Cable-Stayed Bridge with Span Length of 1000-m Scale [J]. Bridge Construction, 2009, 2: 58-60.

Google Scholar

[7] Ronggui Liu, Xianghua Gong. Study on Anchoring Property of CFRP Cables for Stayed Bridges [J]. Industrial Construction, 2006, 36(8): 29-32.

Google Scholar

[8] Ronggui Liu, Fei Xu. Finite Element Analysis of Bonding Anchors for Experimental Bridge with CFRP Csbles [J]. Industrial Construction, 2009, 39(436): 61-64.

Google Scholar

[9] Kuihua Mei, Zhi-tao Lv. Study of Static Load Tests of CFRP Stay Cable Anchors[J]. Bridge Construction, 2005, 4: 20-23.

Google Scholar

[10] JGJ85-2002Technical specification for application of anchorage, gripand coupler for prestressing tendons[S]. Beijin, (2002).

Google Scholar

[11] Tianyong Jiang. Experimental and Theoretical Investigation on the Anchorage System for CFRP Tendons [D]. Hu Nan: Hu Nan University, (2008).

Google Scholar