Studies on Citronellal Extract Column Reflux Ratio and Theoretical Plate Number Design

Article Preview

Abstract:

In this paper, the batch rectification operation is adopted to keep distillate constituting constant high vacuum, in the operation process, the operation of variable reflux ratio is carries out. Through studying the relational system of reflux ratio, column top product composition, rectification time and theoretical plate number, when the concentration of citronellal extract column product is 99%, the appropriate reflux ratio is 0.8-15, and the graphic method is used to design13 pieces of theoretical plate number of citronellal extract column, providing powerful data support for the process design of citronellal extract column.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

331-335

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Luo Jinyue, An Xinnan. Plant Essential Oil and Natural Coloring Agent [M], Chemical Industry Press, 2005. 1.

Google Scholar

[2] Chen Minheng et al., Principles of Chemical Engineering [M], Chemical Industry Press, (2000).

Google Scholar

[3] Qiuchen, Vapor-Liquid Equilibrium Data of Citronella Oil Systems, 2011 Fourth international conference on information management , innovation management and industrial engineering, (2011).

DOI: 10.1109/iciii.2011.297

Google Scholar

[4] Fan Lei et al., Process Calculation for Citronella Oil Batch Rectification Column [M], Chemical Engineering Design, 2006 (3).

Google Scholar