p.375
p.379
p.383
p.387
p.393
p.399
p.404
p.409
p.413
Analysis of Microstructure Abnormal of P91 in Water Storage Tank of Super-Critical Units Caused by Impropriety Heat Treatment
Abstract:
Hardness heterogeneous on weld metal and base metal in complicate structure of water storage tank was found after examination. Replica metallographic examination in hardness heterogeneous zone shows abnormal microstructures. Ostwald Ripening structure was caused by uneven temperature control during heat treatment. Lower cooling speed is the main cause of forming tempered sorbite in weld joints.