Preliminary Study on the Effect of Operating Conditions on the Measurement Accuracy of Electronic Type Electric Energy Meter

Article Preview

Abstract:

The verification of electronic type electric energy meter is under strict reference conditions, but some special operating conditions at locale will exceed the standard scopes. In order to improve the calculation accuracy and operating reliability of electric energy meter under operating conditions, it is necessary to study the operating conditions. According to the working principle and the standard verification regulation of electronic type electric energy meter, this paper summarizes these operating conditions: low power factor, harmonic waves, dynamic impulsive load, voltage fluctuation and outside magnetic field of power frequency, then analyzes the causes of operating conditions and their influence on electronic type electric energy meter, eventually lays foundation for thorough and systematic study of electric energy meter in the operating conditions, and establishes measurement center database of operating conditions.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 834-836)

Pages:

1246-1250

Citation:

Online since:

October 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Huang Jie. National Metrology Technique Laws and Regulations Issued in 2012. China Metrology, 2013(1): 130-131. (in Chinese).

Google Scholar

[2] Lan Yonglin. The Metrology of AC Electric Energy [M]. Beijing: China Zhijian publishing House, 2011. (in Chinese).

Google Scholar

[3] Zheng Rao, Li Zhaohua, Tan Jinchao. Manual of Electric Energy Metrology [M]. China Power Press, 2002. (in Chinese).

Google Scholar

[4] Han Zhenxiang. Power System Analysis [M], Zhejiang University Press, 2005. (in Chinese).

Google Scholar

[5] Wang Baojuan, Yao Songheng. The Study of Metering Error in Electronic Type Electric Energy meter[J]. Papers Assembly of 10th Anniversary of China AAST and Industrial City Strategic Forum, 2008. (in Chinese).

Google Scholar

[6] LU Shiwei, WANG Long. Analysis on Test-running Results of Multi-functional Energy Meter under Harmonic Operating Conditions[J] Instrumentation technology, 2011(002): 3-5. (in Chinese).

Google Scholar

[7] Tan Zhiqiang, Peng Chuning. The Influence on Electric Energy Measurement Under the Condition of Impulse Load[J]. Electrical Measurement & Instrumentation, 2003, vol (1): 41-43. (in Chinese).

Google Scholar

[8] Pan Jiefeng, Gong Mingbo. The Harmfulness of Inductive Lightning to the Single Phase Electric Meter and Its Protective Measures[J]. ZHEJIANGELECTRICPOWER, 2005, 24(2): 63-64. (in Chinese).

Google Scholar

[9] Zhou Bihong, Shi Leibing, Han Zhiqiang, . etc The Magnetic Field of Power Frequency [J]. Shanghai Measurement and Testing, 2011, 6: 021. (in Chinese).

Google Scholar

[10] Li Qin. Electromagnetic Interference Effects and Restraint Strategy on Electronic Type Electric Energy Meters [J]. Electrical Measurement & Instrumentation, 2007, 44(6): 50-54. (in Chinese).

Google Scholar