Transmission Tower Collapse Analysis with Wind Load Based on LS-DYNA

Article Preview

Abstract:

Large span transmission tower is the lifeline of electricity transmission,Its collapse destroyed will causes adverse to the social and economic effects,The mechanism of the power transmission tower collapsed caused people's attention.The analysis is based on LS-DYNA program,explicit beam161 beam element is adopted to establish the finite element model for transmission towers,Analyses the collapse process of transmission tower and its failure mode with downburst load.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 838-841)

Pages:

370-374

Citation:

Online since:

November 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Oliver S. E., Moriarty W. W., Holmes J. D. A risk model for design of transmission line systems against thunderstorm downburst winds [J]. Engineering Structures, 2000, 22(9): 1173-1179.

DOI: 10.1016/s0141-0296(99)00057-7

Google Scholar

[2] Savory E., Parke G., Zeinoddini M., et al. Modeling of tornado and microburst- induced wind loading and failure of a lattice transmission tower [J]. Eng. Struct. 2001, (23): 365–375.

DOI: 10.1016/s0141-0296(00)00045-6

Google Scholar

[3] Shehata A.Y., EI Damatty A.A., Savory E. Finite element modeling of transmission line under downburst wind loading [J]. Finite Elem. Anal. Des. 2005 (42): 71-89.

DOI: 10.1016/j.finel.2005.05.005

Google Scholar

[4] Shehata, A.Y., El Damatty, A.A. Assessment of the failure of an electrical transmission line due to a downburst event[C]. Structural Reliability in a Changing World - Proceedings of the 2006 Electrical Transmission Conference, 2006: 27-38.

DOI: 10.1061/40790(218)3

Google Scholar

[5] Shehata A.Y., EI Damatty A.A. Behaviour of guyed transmission line structures under downburst wind loading[J]. Wind Struct, 2007. 10 (3): 249-268.

DOI: 10.12989/was.2007.10.3.249

Google Scholar

[6] Hoxey R., Robertson A., Toy N., et al. Design of an experimental arrangement to study the wind loads on transmission towers due to downbursts [J]. Advances in Fluid Mechanics, 2003, 36: 395-404.

Google Scholar

[7] Fujita TT. Manual of downburst identification for project NIMROD[R]. SMRP Research paper 156, University of chicago, 104pp. [NTIS PB-286048], (1978).

Google Scholar

[8] Letchford CW, Mans C, Chay MT. Thunderstorms—their importance in wind engineering, a case for the next generation wind tunnel[J]. Journal of Wind Engineering and Industrial Aerodynamics, 2002, 90(12-15): 1415-1433.

DOI: 10.1016/s0167-6105(02)00262-3

Google Scholar

[9] Holmes JD. Modeling of extreme thunderstorm winds for wind loading of structures and risk assessment[A]. 10th International Conference on Wind Engineering, Copenhagen, Denmark, 1999, 1409–1415.

Google Scholar

[10] Chen L, Letchford CW. Multi-scale correlation analyses of two lateral profiles of full-scale downburst wind speeds[J]. Wind Eng. Ind. Aerodyn. 2006, 94 (9): 675–696.

DOI: 10.1016/j.jweia.2006.01.021

Google Scholar