Abstract:

The fiber sensor based on SPR, surface plasmon resonance, could effectively overcome the shortcomings of the existing measurement methods of oil in waste water, such as outdated detection ways, low measurement accuracy, poor adaptive ability environment, and so on, and it had extensive research and application value. On the basis of analyzing the principle of SPR, the fiber sensor based on SPR was designed and the system structure model was given. The solutions of oil and waste water with different concentrations were tested and the relation between resonant wavelength of SPR spectra and refractive index of the tested solutions were obtained. The experiment results show that it is feasible that the fiber testing technology is used to measure the oil in waste water, and the study has certain significance in sewage disposal for the petrochemical industry and water reuse.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 850-851)

Pages:

1372-1375

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] C. Mouvet, R.D. Harris, C. Maciag, B.J. Luff, J.S. Wilkinson, J. Piehler, A. Brecht, G. Gauglitz, R. Abuknesha and G. Ismail: Determination of Simazine in Water Samples by Wavegide surface plasmon resonace. Analytica Chimica Acta, Vol. 338, No. 1, (1997).

DOI: 10.1016/s0003-2670(96)00443-6

Google Scholar

[2] M. Shimomura, Y. Nomura, W. Zhang, M. Sakino, K. Ho. Lee, K. Ikebukuro and I. Karube: Simple and rapid detection method using surface plasmon resonance for dioxins. Polychlorinated biphenylx and atrazine. Analytica Chimica Acta, Vol. 434, No. 2, (2001).

DOI: 10.1016/s0003-2670(01)00809-1

Google Scholar

[3] E. Kretschmann: The determination of the optical constants of metals by excitation of surface plasmons. Z. Physik, Vol. 241, No. 4, (1971), pp.313-324.

Google Scholar

[4] S. Trosok, B. Driscoll and J. Luong: Mediated microbial biosensor using a novel yeast strain for wastewater BOD measurement. Applied micreobiology and biotechnology, Vo. 56, No. 3-4, (2001), pp.550-554.

DOI: 10.1007/s002530100674

Google Scholar

[5] N. Yoshida, S. J. McNiven, A. Yoshida, T. Morita, H. Nakamura and I. Karube: A compact optical system for multi-determination of biochemical oxygen demand using disposable strips. Field analytical chemistry and technology, Vol. 5, No. 5, (2001).

DOI: 10.1002/fact.10001

Google Scholar

[6] R.L. Meyer, T. Kjaer and N.P. Revsbech: Use of NOx-microsensors to estimate the activity of sediment nitrification and NOx- consumption along an estuarine salinity, nitrate, and light gradient. Aquatic microbial ecology, Vol. 26, No. 2, (2001).

DOI: 10.3354/ame026181

Google Scholar

[7] Z.W. Zhang, W.F. Yin, T.D. Wen, L.Q. Zhu and J.L. Zhang: Study on the relation expression of solution concentration and its refractive index. Journal of north university of China(Natural science edition). Vol. 30, No. 3, (2009), pp.281-285.

Google Scholar