Research on Speed Control Model with Temperature in Hydraulically-Driven Cooling Fan

Article Preview

Abstract:

In order to obtain excellent cooling module, it is necessary to make air flow flowing into the radiator vary with ambient temperature. Cooling fan speed must vary with cooling power continuously. In this paper, the relation was obtained between fan speed and flow, static pressure, torque, power based on calculation and performance test data related to cooling fan. The mathematical model between fan speed and heat dissipation power in cooling module was deduced. Driving characteristics of cooling fan were analyzed.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 850-851)

Pages:

350-354

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Q.Y. Li: The Ventilator (China Machine Press, 1981).

Google Scholar

[2] G. Shang, B. Wen, M. Wu, Y.Y. Wang D.L. Liu: Calculation Method of Aerodynamic Performances of Engine Cooling Fans, Vol. 32 (2010) No. 9, pp.709-802.

Google Scholar

[3] B.L. Wu, Y.F. Gao: Air Cooling Axial Flow Ventilator (Harbin Institute of Technology Press, 2007).

Google Scholar

[4] Timothy C Scott, Dhananjay S Josh: Engine Cooling Module Sizing Using Combined 1-Dimensional and CFD Modeling Tools, Vol. 1 (2009) No. 1177.

Google Scholar

[5] Q.H. Lin: Energy Saving of Pump and Fan (water resources and electric power press, 1987).

Google Scholar