Controlling and Testing of the Uneven Wall Surface

Article Preview

Abstract:

Paper deals with practices significantly affecting quality and durability of external thermal insulation of the building envelope. Analysis is made by the survey of existing external constructions of buildings, experimental detection of bearing capacity of expansion anchors, including theoretical modelling of their activity in the external wall processed by the ANSYS program. Paper briefly summarizes new findings detected by control and testing activities for additional thermal protection of the building envelope.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

387-392

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J. Bizub: Application of contact insulating systems in terms of building supervision. (in Slovak) TECHSTAV (2007).

Google Scholar

[2] M. Fraštia: Photogrammetric measurement of building component shape. (in Slovak) In.: Geodesy and Photogrammetry Reminiscence. SvF STU Bratislava, 2009 ISBN 978-80-227-3045-7.

Google Scholar

[3] J. Králik: Reliability Analysis of Stuctures Using Stochastic Finite Element Method. Published by STU Bratislava, 2009 143pp. ISBN 978-80-227-3130-0.

Google Scholar

[4] M. Nič, M. Fraštia, J. Nováčiková: Photogrammetric determination of built-up volume. (in Slovak) In: Soudní inženýrství, 2/2006, VUT Brno. ISNN 121-443X.

Google Scholar

[5] J. Nováčiková: Control and testing action and additional thermal insulation of external envelopes of buildings. (in Slovak) Thesis. SvF STU Bratislava, (2010).

Google Scholar

[6] P. Turček, I. Slávik: Foundation engineering. (in Slovak) STU Bratislava ISBN 80-227-1699-5.

Google Scholar

[7] Z. Sternová et al.: Renovation of residential buildings – mulitiple housing up to 1970. (in Slovak) Jaga group, v. o. s., Bratislava 2001, ISBN 80-88905-53-2.

Google Scholar

[8] Z. Sternová et al.: Renovation of residential buildings – mulitiple housing after 1970 (in Slovak) Jaga group, v. o. s., Bratislava 2002, ISBN 80-88905-68-0.

Google Scholar

[9] P. Vlček, K. Kubečka, D. Kubečková, H. Vaculíková: Defects of insulation systems and their negative effect on the accumulation and energy saving. In: Advanced Materials Research, volume 649, p.143 – 146. ISSN: 10226680 ISBN: 978-303785596-6.

DOI: 10.4028/www.scientific.net/amr.649.143

Google Scholar