Performance Evaluation of a Wind Power-Augmented Device on an Onsite Exhaust Air Energy Recovery Wind Turbine

Article Preview

Abstract:

This paper presents an idea on generating green energy by extracting discharged wind energy from a cooling tower. Two vertical axis wind turbines (VAWTs) integrated with a wind power-augmentation device are installed above a cooling tower to harness unnatural wind for electricity generation. The wind power-augmentation device is built with several guide-vanes and diffuser-plates to improve the performance of the VAWTs. Guide-vanes are designed to create a venturi effect and guide the on-coming wind stream to an optimum flow angle which is matched to the optimum angle of attack of the VAWTs. Diffuser-plates are tilted at an optimum angle to draw more wind and accelerate the discharged airflow. From the laboratory test, the VAWTs performance was increased by 7 – 8 % when guide-vanes and diffuser-plates are installed at their optimum angle. The correct matching of VAWTs for this system is expected to generate electricity at their rated power constantly when the cooling tower is in operation. This system can contribute to the reduction of greenhouse gases emission and conservation of the environment for a healthier life since fossil fuel consumption for energy generation is reduced as well as efficient use of energy.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

126-129

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] R.A. Fuller, K.J. Gaston, The scaling of green space coverage in European cities, Biology Letters, 5 (2009) 352-355.

DOI: 10.1098/rsbl.2009.0010

Google Scholar

[2] Y. Ohya, T. Karasudani, A. Sakurai, K. -i. Abe, M. Inoue, Development of a shrouded wind turbine with a flanged diffuser, Journal of Wind Engineering and Industrial Aerodynamics, 96 (2008) 524-539.

DOI: 10.1016/j.jweia.2008.01.006

Google Scholar

[3] M. Kardous, R. Chaker, F. Aloui, S.B. Nasrallah, On the dependence of an empty flanged diffuser performance on flange height: Numerical simulations and PIV visualizations, Renewable Energy, (2012).

DOI: 10.1016/j.renene.2012.09.061

Google Scholar

[4] F. -B. Hsiao, C. -J. Bai, W. -T. Chong, The Performance Test of Three Different Horizontal Axis Wind Turbine (HAWT) Blade Shapes Using Experimental and Numerical Methods, Energies, 6 (2013) 2784-2803.

DOI: 10.3390/en6062784

Google Scholar

[5] W.T. Chong, A. Fazlizan, S.C. Poh, K.C. Pan, H.W. Ping, Early development of an innovative building integrated wind, solar and rain water harvester for urban high rise application, Energy and Buildings, 47 (2012) 201-207.

DOI: 10.1016/j.enbuild.2011.11.041

Google Scholar

[6] T. Khatib, K. Sopian, A. Mohamed, M.Z. Ibrahim, Sizing of a wind charger at minimum cost for remote housing electrification: A case study for nine coastal sites in Malaysia, Energy and Buildings, 51 (2012) 185-190.

DOI: 10.1016/j.enbuild.2012.05.001

Google Scholar