Measurement on Gas Number Density Distribution by Tunable Diode Laser Absorption Spectroscopy

Article Preview

Abstract:

An experimental technique was designed to measure the gas number density distribution of alkali vapor by tunable diode laser absorption spectroscopy. The measurement method was developed by scanning multiple gas absorption lines and fitting the experiment data with Lorentz profile to obtain the density. A discretization strategy of the equation for absorption lines is also present here as well as a constrained liner least-square fitting method. A simulation model was set up to reconstruct the two-dimensional distribution of number density and the feasibility of the reconstruction was verified. In the end, this work demonstrates the calculation error of the acquired number density and the distribution. The results indicated that the error would be no more than 5% if the measurement error is less than 9%.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

1523-1526

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Kielkopf J F. On the precise evaluation of the complete semiclassical spectral line shape for pressure-broadened atomic spectral lines[J]. Journal of Physics B: Atomic and Molecular Physics, 1976, 9(9): 1601.

DOI: 10.1088/0022-3700/9/9/023

Google Scholar

[2] Allard N, Kielkopf J. The effect of neutral nonresonant collisions on atomic spectral lines[J]. Reviews of modern physics, 1982, 54(4): 1103.

DOI: 10.1103/revmodphys.54.1103

Google Scholar

[3] Szudy J, Baylis W E. Profiles of line wings and rainbow satellites associated with optical and radiative collisions[J]. Physics reports, 1996, 266(3): 127-227.

DOI: 10.1016/0370-1573(95)00054-2

Google Scholar

[4] Kluttz K A, Averett T D, Wolin B A. Pressure broadening and frequency shift of the D1 and D2 lines of Rb and K in the presence of 3 He and N 2[J]. Physical Review A, 2013, 87(3): 032516.

Google Scholar

[5] Forouhar S, Briggs R M, Frez C, et al. High-power laterally coupled distributed-feedback GaSb-based diode lasers at 2 μm wavelength[J]. Applied Physics Letters, 2012, 100(3): 031107.

DOI: 10.1063/1.3678187

Google Scholar

[6] Cui X, Lengignon C, Tao W, et al. Photonic sensing of the atmosphere by absorption spectroscopy[J]. Journal of Quantitative Spectroscopy and Radiative Transfer, 2012, 113(11): 1300-1316.

DOI: 10.1016/j.jqsrt.2011.11.008

Google Scholar

[7] Wang J, Maiorov M, Jeffries J B, et al. A potential remote sensor of CO in vehicle exhausts using 2.3 µm diode lasers[J]. Measurement Science and Technology, 2000, 11(11): 1576.

DOI: 10.1088/0957-0233/11/11/306

Google Scholar

[8] Jian W, Wei H, Haitao G. Gas temperature measurement with tunable diode laser absorption spectroscopy[J]. Acta Optica Sinica, 2007, 27(9): 1639.

Google Scholar

[9] Liu X, Zhou X, Jeffries J B, et al. Experimental study of H<sub> 2</sub> O spectroscopic parameters in the near-IR (6940–7440cm<sup>− 1</sup>) for gas sensing applications at elevated temperature[J]. Journal of Quantitative Spectroscopy and Radiative Transfer, 2007, 103(3): 565-577.

DOI: 10.1016/j.jqsrt.2006.07.008

Google Scholar

[10] Nikkari J J, Di Iorio J M, Thomson M J. <i> In Situ</i> Combustion Measurements of CO, H<sub> 2</sub> O, and Temperature with a 1.58-μm Diode Laser and Two-Tone Frequency Modulation[J]. Applied optics, 2002, 41(3): 446-452.

DOI: 10.1364/ao.41.000446

Google Scholar

[11] Seltzer S J. Developments in Alkali-metal Atomic Magnetometry[D]. Princeton: Princeton University, (2008).

Google Scholar