Analyzing the active power loss of reactive power compensation device under normal reactive power output status and its influence factors and metering the active power loss of the reactor in the 500kV substation and the capacitor in the 220kV substation, concluding that the active power meter had the influencing factors of forward and reverse active and putting forward the assessment requirements for the running reactive power compensation device by analyzing the site calibration data of metering device.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

1638-1642

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] YAO Liang-zhu. Discussion on optimizing reactive compensation to decrease line loss [J]. Automation of Electric Power Systems, 2002, 22(12): 71-73.

Google Scholar

[2] GUO Rui, LIU Guo-hai. Study on STATCOM model and its control strategy [J]. Electric Power Automation Equipment , 2006, 26( 1): 21-24.

Google Scholar

[3] SONG Shan, CHEN Jian-ye. Theory and prototype verification of thyristor based STATCOM [J]. Automation of Electric Power Systems, 2006, 30(18): 49-54.

Google Scholar

[4] FENG Yu-cheng, CHEN Chen. Comparison and analysis between static synchronous compensator and traditionary static var compensator [J] . Power of East China, 2005, 33(9): 16-19.

Google Scholar

[5] ZHOU Jian-feng, GU Ya-qin, WEI Shou-qi, et al. Comprehensive comparative analysis of SVC and STATCOM [J]. Electric Power Automation Equipment, 2007, 27(12): 57-61.

Google Scholar

[6] YU Meng-ze, CHEN Bai-chao, TIAN Cui-hua, et al. High voltage static var reactive power compensator using shunt magnetically controllable reactor [J]. High Voltage Engineering, 2009, 35(7): 1770-1773.

Google Scholar

[7] LI Shan-ying, SHI Qing-xin. Study on reactive power compensation for the integration and operation of large-scale wind farms [J]. Electric Power, 2010, 43(9): 71-74.

Google Scholar

[8] VARMA R K, AUDDY S, SEMSEDINI Y. Mitigation of sub-synchronous resonance in a series-compensated wind farm using FACTS controllers [J]. IEEE Transactions on Power Delivery, 2008, 23(3): 1645-1655.

DOI: 10.1109/tpwrd.2008.917699

Google Scholar

[9] XU Hong-bing. Analysis on economic operation of shunt capacitor for reactive power compensation [J]. Power Capacitor & Reactive Power Compensation, 2006, (12): 12-14.

Google Scholar

[10] SHI Huan, HUANG Xiao-sheng, ZENG Wen-jun, et al. Dynamic reactive power compensation device based on magnetically controlled reactor [J]. Electric Power, 2011, 44(1): 32-36.

Google Scholar

[11] KONG Bin, WEI Ya, LIU Xian-lin. Electric energy dissipation analysis of parallel condenser based on harmonic wave [J]. Journal of Zhengzhou University (Engineering Science), 2003, 24(3) 98-100.

Google Scholar