The Design of Location System for Single-Phase Grounded Fault in Distribution Network Based on Zero-Sequence Current

Article Preview

Abstract:

In this paper, A location system for single phase grounded fault in distribution network is proposed and it is based on the phase of zero-sequence current. The system is composed of central station and nodes installed on the power line, and their functions are illustrated in this paper. The principle of the method is shown and experiments are carried out. The results show that the feasibility of the method. The advantage of this method is it’s short time to detect. The method is Applicable to detect the faulty segment for neutral point non-grounded system with grounded resistance less than 1kΩ.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

1677-1681

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Bo, Z.Q., Weller, G., Redfern, M.A. Accurate fault location technique for distribution system using fault-generated high-frequency transient voltage signals[J]. Generation, Transmission and Distribution, IEE Proceedings-, 1999, V146 (1): 73-79.

DOI: 10.1049/ip-gtd:19990074

Google Scholar

[2] QUAN Yu- sheng , LI Ping, ZHANG Yu. A new-one terminal fault location algorithm based on differential equation[J]. Power System Technology, 2004, 28(21): 47-51.

Google Scholar

[3] Zhang Huifen, Pan Zhencun, Sang Zaizhong, et al. Injecting current based method fro fault location in neutral isolated power system[J]. Automation of Electric Power Systems, 2004, 28(3): 64-66( in Chinese ).

Google Scholar

[4] WANG Nan, ZHANG Li, YANG Yi-han. A comprehensive location method using AC/DC signal injecting for single-phase earth fault in 10 kV distribution network[J]. Power System Technology, 2008, 32(24): 88-92.

Google Scholar

[5] YU Sheng-nan, BAO Hai, YANG Yi-han. Practicalization of fault location in distribution lines[J]. Proceedings of the CSEE, 2008, 28(28): 86-90.

Google Scholar

[6] YAN Feng, YANG Qi-xun, QI Zheng, et al. Study on fault location scheme for distribution network based on traveling wave theory[J]. Proceedings of the CSEE, 2004, 24(9): 37-43.

Google Scholar

[7] ZHANG Fan, PAN Zhen-cun, ZHANG Hui-fen, et al. New algorithm based on traveling wave for location of single phase to ground fault in tree type distribution network[J]. Proceedings of the CSEE, 2007, 27(18): 46-52.

Google Scholar

[8] Xu Gang, Yu Sheng, Xu Zhenyu. Fault location for interline fault of parallel transmission lines using one-terminal data[C], 2009 Asia-Pacific Power and Energy-Engineering Conference, APPEEC 2009 Proceedings.

DOI: 10.1109/appeec.2009.4918377

Google Scholar

[9] Yuansheng Liang, Jingmei Guo, Gang Wang. Parameter self-adaptive fault location of four-parallel transmission lines on the same tower[C]. 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2011: 1-4.

DOI: 10.1109/drpt.2011.5994016

Google Scholar