Study on Simulation Model on Partial Discharge in Void of Solid Insulation

Article Preview

Abstract:

In order to analyze the partial discharge of void defect discharge in solid insulator, for the PD problems that at home and abroad simulation model can’t objectively reflect the physical process of partial discharge. Based on classical three capacitor equivalent-circuit model, the change of the electric field intensity and the voltage as size of the air void differs is studied. The influence of the air void geometry properties of partial discharge is analyzed. By comparing the results of the simulation model and its results and existing research results, the correctness of the circuit simulation model is verified.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

2014-2018

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] M. D. Judd,S. D. J. McArthur,J. R. McDonald and O. Farish,Intelligent condition monitoring and asset management:Partial discharge monitoring for power transformers, ,IEE Power Engineering Journal,2002,Vol. 16,No. 6,pp.297-304.

DOI: 10.1049/pe:20020603

Google Scholar

[2] Niemeye L. A generalized approach to partial discharge modeling[J]. IEEE Transaction on Dielectrics and Electrical Insulation,1995,2(4): 510-528.

Google Scholar

[3] Gutfleisch F,Niemeye L. Measurement and simulation of PD in epoxy voids [J]. IEEE Transaction on Di electrics and Electrical Insulation,1995,2(5): 729-743.

DOI: 10.1109/94.469970

Google Scholar

[4] KUPERSHTOKH A L,STAMATELATOS C,AGORISs D P. Stochastic model of partial discharge activity in liquid and solid dielectrics. Novosibirsk[C]. Russia: International Conference on Dielectric Liquids,2005: 135-138.

DOI: 10.1109/icdl.2005.1490045

Google Scholar

[5] Kolev N P, Darjanov P I, Gadjeva E D, et al. A new computer model for partial discharge phenomena investigations[A]. The IEEE Electrical Insulation Conference and Electrical Manufacturing and Coil Windings Conference, Rosemont, USA, (1997).

DOI: 10.1109/eeic.1997.651107

Google Scholar

[6] Kolev NP, Danikasmg, Gadjeva E D, et al. Development of partial discharge model, simulation and measurement[A]. IEEE Conference on Electrical Insulation and Dielectric Phenomena, Austin, USA, (1999).

DOI: 10.1109/ceidp.1999.804629

Google Scholar

[7] CHAMPION J V,DODD S J,ALISON J M. The Correlation between the Partial Discharge Behavior and the Spatial and Temporal Development of Electrical Trees Grown in an Epoxy Resin[J]. J. Phys. D: Appl. Phys., 1996,29(4):2689-2695.

DOI: 10.1088/0022-3727/29/10/023

Google Scholar

[8] CHIA P Y,LIEW A C. Novel approach to partial discharge signals modeling in dielectric insulation void using extension of lumped capacitance mode[C]. Perth, Australia: International Conference on Power System Technology,2000: 1207-1212.

DOI: 10.1109/icpst.2000.898141

Google Scholar

[9] REN Cheng-yan, CHENG Yong-hong, CHEN Xiao-lin, etc. Simulation calculation of partial discharge in single void using variable void resistance molel[J]. Journal of Xi'an Jiaotong University, 2004, 38(10): 1018-1021.

Google Scholar

[10] CHEN Xiao-lin, CHENG Yong-hong, REN Cheng-yan, etc. Study on modifying the simulation model and computing the key parameters of partial in single void. [J]. Journal of Xi'an Jiaotong University, 2004, 38(8): 815-819.

Google Scholar

[11] Lihua Chen, Zhong Zheng, Min Chen, Hong Yu The study of the discharge mechanism and characteristics of micro-voids in the solid dielectric[A]. International Conference on High Voltage Engineering and Application, Shanghai, China, (2012).

DOI: 10.1109/ichve.2012.6357048

Google Scholar