Determination of the Possible Causes of Cracks in Pins of Quick Operating Valves in Hydroelectric Power Plant

Article Preview

Abstract:

During the revision of the individual parts of a hydroelectric power plant the cracks in the pins of quick operating and revision flap valves of Francis turbine were found. Our department has been approached with a request to investigate the causes of these cracks. This paper deals with the complex analysis of influential factors, especially the measurements of residual stresses by hole-drilling method, in order to reveal the factors causing the cracks in the pins.

You have full access to the following eBook

Info:

* - Corresponding Author

[1] Trebuňa F. et al., Expertíza tabúľ provizórneho hradenia vtokov TG1 a TG2 vo VE Ružín I, TU Košice, (2004).

Google Scholar

[2] Istenes, I.: Vyhodnotenie trhlín na čapoch klapkových uzáveroch z TJ Ružín. ROEZ Stress Analysis. Bratislava, (2012).

Google Scholar

[3] Trebuňa, F., Šimčák, F.: Kvantifikácia zvyškových napätí tenzometrickými metódami. Prešov, Grafotlač (2005).

Google Scholar

[4] ASTM E837-08 Standard Test Method for Determining Residual Stresses by the Hole-Drilling Strain-Gage Method, USA, (2009).

DOI: 10.1520/e0837-13

Google Scholar

[5] Trebuňa F. et al., Výpočet zbytkovej životnosti klapiek pre sústrojenstvo TG1 a TG2 PVE Ružín, (2012).