Application of Dynamic Voltage Restorer for Power Quality Improvement in Low Voltage Electrical Power Distribution Network: An Overview

Article Preview

Abstract:

Dynamic Voltage Restorer (DVR) is a series connected power electronics based custom power device that is used to improve voltage disturbances in low voltage electrical power distribution network. Power quality requirement is one of the most important concerns for power system. The parts of the DVR is made up of voltage source inverter, injection/booster transformer, a harmonic filter, an energy storage device and a bypass switch. The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control. This paper presents a review of the researches on the dynamic voltage restorer application for power quality improvement in low voltage electrical power distribution networks. It describes power quality issues, principle of operation of DVR, basic components of DVR, DVRs control topologies in distribution network, DVR control strategies and compensation techniques.

You might also be interested in these eBooks

Info:

Pages:

142-156

Citation:

Online since:

January 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. De Keulenaer, The hidden cost of poor power quality, European copper institute. (2003).

Google Scholar

[2] S.W. Middlekauff, E.R. Collins Jr, System and Customer Impact Considerations for Series Custom Power Devices, IEEE Transactions on Power Delivery. 13(1) (1998) 278-282.

DOI: 10.1109/61.660890

Google Scholar

[3] P. Roncero-Sanchez, E. Acha, Dynamic voltage restorer based on flying capacitor multilevel converters operated by repetitive control, Power Delivery, IEEE Transactions on. 24(2) (2009) 951-960.

DOI: 10.1109/tpwrd.2008.2005885

Google Scholar

[4] Rosli Omar, et al, Dynamic Voltage Restorer Application for Power Quality Improvement in Electrical Distribution System, An Overview. Australian Journal of Basic and Applied Sciences. (2011).

Google Scholar

[5] M.J. Newman, D.G. Holmes, J.G. Nielsen, F. Blaabjerg, A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level, Industry Applications, IEEE Transactions. 41 (2003) 1744-1753.

DOI: 10.1109/tia.2005.858212

Google Scholar

[6] F.A. L Jowder, Design and analysis of dynamic voltage restorer for deep voltage sag and harmonic compensation, Generation, Transmission & Distribution. 3 (, 2009) 547-560.

DOI: 10.1049/iet-gtd.2008.0531

Google Scholar

[7] E. Babaei, M. F. Kangarlu, Sensitive load voltage compensation against voltage sags/swells and harmonics in the grid voltage and limit downstream fault currents using DVR, Electric Power Systems Research. 83(1) (2012) 80-90.

DOI: 10.1016/j.epsr.2011.09.013

Google Scholar

[8] Y.W. Li, M. Vilathgamuwa, D.P. Chiang Loh, F. Blaabjerg, A dual-functional medium voltage level DVR to limit downstream fault currents", Power Electronics, IEEE Transactions. 22 (2007) 1330-1340.

DOI: 10.1109/tpel.2007.900589

Google Scholar

[9] M. H. Bollen, Understanding power quality Problems, IEEE press New York, USA, (2000).

Google Scholar

[10] A. Ghosh, et al, Design of a capacitor-supported dynamic voltage restorer (DVR) for unbalanced and distorted loads, Power Delivery, IEEE Transactions on. 19(1) (2004) 405-413.

DOI: 10.1109/tpwrd.2003.820198

Google Scholar

[11] S.S. Choi, B.H. Li, D.M. Vilathgamuwa, A comparative study of inverter- and line-side filtering schemes in the dynamic voltage restorer, IEEE Power Engineering Society Winter Meeting. 4 (2000) 2967-2972.

DOI: 10.1109/pesw.2000.847357

Google Scholar

[12] J. G. Nielsen, F. Blaabjerg, A detailed comparison of system topologies for dynamic voltage restorers, Industry Applications, IEEE Transactions on. 41(5) (2005) 1272-1280.

DOI: 10.1109/tia.2005.855045

Google Scholar

[13] R. C. Dugan, M. F. McGranaghan, S. Santoso, H. Wayne Beaty: , Electrical Power Systems Quality second edition, McGraw-Hill, New York, (2002).

Google Scholar

[14] IEEE Standard 100-1992, IEEE Standard Dictionary of Electrical and Electronic Terms.

Google Scholar

[15] IEC 61000-4-30 77A/356/CDV, Power Quality Measurement Methods. (2001).

Google Scholar

[16] C. Benachaiba, B. Ferdi, Power Quality Improvement Using DVR, American Journal of Applied Sciences, vol. 6 issue 3, (2009) 396-400.

DOI: 10.3844/ajas.2009.396.400

Google Scholar

[17] R. Omar, N.A. Rahim, Modeling and simulation for voltage sags/swells mitigation using dynamic voltage restorer (DVR), "Power Engineering Conference, 2008. AUPEC , 08. Australasian Universities, vol. 1, no. 5, (2008) 14-17.

DOI: 10.1109/aupec.2017.8282438

Google Scholar

[18] M.H.J. Bollen, Understanding power quality problems, Vol. 3. New York: IEEE press, (2000).

Google Scholar

[19] A. Pakharia, M. Gupta, Dynamic Voltage Restorer for Compensation of Voltage Sag and Swell: A Literature Review, International Journal of Advance in Engineering & Technology, vol 4, issue 1, (2012) 347-355.

DOI: 10.31142/ijtsrd23740

Google Scholar

[20] J. Stones, & A. Collinson, Power quality, Power Eng. Journal, vol. 15, no. 2, (2001) 58-64.

Google Scholar

[21] M. H. J Bollen, What is power quality?, Electric Power Systems Research, vol. 66, no. 1, (2003) 5-14.

Google Scholar

[22] A. El Mofty, K. Youssef, Industrial power quality problems, Electricity Distribution, Part 1: Contributions. CIRED. 16th International Conference and Exhibition on (IEE Conf. Publ No. 482), vol. 2, no., 5 (2001).

DOI: 10.1049/cp:20010757

Google Scholar

[23] W.E. Reid, Power quality issues-standards and guidelines, Industry Applications, IEEE Transactions on, vol. 32, no. 3, (1996) 625-632.

DOI: 10.1109/28.502175

Google Scholar

[24] S.J. Lee, H. Kim, S.K. Sul, A novel control algorithm for static series compensators by use of PQR instantaneous power theory, IEEE Trans on Power Electronics. 19(3) (2004) 814-827.

DOI: 10.1109/tpel.2004.826499

Google Scholar

[25] S.S. Mahesh, M.K. Mishra, B.K. Kumar, V. Jayashankar, Rating and design issues of DVR injection transformer", Applied Power Electronics Conference and Exposition. (2008) 449-455.

DOI: 10.1109/apec.2008.4522760

Google Scholar

[26] P.K.W. Chan, K.K.S. Leung, H.S.H. Chung, S.Y.R. Hui, Boundary controller for dynamic voltage restorers to achieve fast dynamic response, Applied Power Electronics Conference and Exposition. (2006) 6.

DOI: 10.1109/apec.2006.1620719

Google Scholar

[27] A. Ghosh, G. Ledwich, Compensation of distribution system voltage using DVR, Power Delivery, IEEE Transactions on, vol. 17, no. 4, (2002) 1030-1036.

DOI: 10.1109/tpwrd.2002.803839

Google Scholar

[28] C.J. Posada, J.M. Ramirez, R.E. Correa, Voltage compensation for common disturbances at the distribution level, Innovative Smart Grid Technologies (ISGT Latin America), IEEE PES Conference on, vol., no16, (2011) 19-21.

DOI: 10.1109/isgt-la.2011.6083182

Google Scholar

[29] N.H. Woodley, L. Morgan, A. Sundaram, Experience with an inverter-based dynamic voltage restorer, Power Delivery, IEEE Transactions on, vol. 14, no. 3, (1999).

DOI: 10.1109/61.772390

Google Scholar

[30] R. Omar, N. Rahim, & M. Sulaiman, Dynamic Voltage Restorer Application for Power Quality Improvement in Electrical Distribution System: An Overview, Australian Journal of Basic and Applied Sciences, vol. 5, no. 12, (2011) 379-396.

Google Scholar

[31] M. Vilathgamuwa, H. W. Wijekoon, Mitigating Zero Sequence Effects in Dynamic Voltage Restorers, Power Electronics Specialists Conference, PESC 2007. IEEE, vol., no., pp.3079-3085, 17-21 June (2007).

DOI: 10.1109/pesc.2007.4342517

Google Scholar

[32] C. Zhan, V.K. Ramachandaramurthy, A. Arulampalam, C. Fitzer, S. Kromlidis,M. Barnes, N. Jenkins, Dynamic voltage restorer based on voltage space vector PWM control, Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual IEEE, vol. 2, (2001).

DOI: 10.1109/apec.2001.912533

Google Scholar

[33] C. Zhan, M. Barnes, V. K Ramachandaramurthy, N. Jenkins, Dynamic voltage restorer with battery energy storage for voltage dip mitigation, Power Electronics and Variable Speed Drives, 2000. Eighth International Conference on (IEE Conf. Publ. No. 475), vol., (2000).

DOI: 10.1049/cp:20000273

Google Scholar

[34] B. H Li, S.S. Choi, D. M. Vilathgamuwa, On the injection transformer used in the dynamic voltage restorer, Power System Technology, 2000. Proceedings. PowerCon 2000. International Conference on, vol. 2, (2000) 941-946.

DOI: 10.1109/icpst.2000.897147

Google Scholar

[35] S. S. Mahesh, M. K. Mishra, B. K. Kumar, V. Jayashankar, Rating and design issues of DVR injection transformer, Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE, vol., no., (2008) 449-455.

DOI: 10.1109/apec.2008.4522760

Google Scholar

[36] H. Kim, J. Kim, S. Sul, A design consideration of output filters for dynamic voltage restorers, Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual, vol. 6, no., (2004).

DOI: 10.1109/pesc.2004.1354755

Google Scholar

[37] S.S. Choi, B. H. Li, D. M. Vilathgamuwa, A comparative study of inverter and line-side filtering schemes in the dynamic voltage restorer, Power Engineering Society Winter Meeting, 2000. IEEE, vol. 4, no., (2000) 2967-2972.

DOI: 10.1109/pesw.2000.847357

Google Scholar

[38] S. S. Choi, B.H. Li, D.M. Vilathgamuwa, Design and Analysis of the Inverter-Side Filter Used in the Dynamic Voltage Restorer, Power Engineering Review, IEEE, vol. 22, no. 4, (2002) 80-80.

DOI: 10.1109/mper.2002.4312158

Google Scholar

[39] S.S. Choi, B. H. Li, D. M. Vilathgamuwa, Design and analysis of the inverter-side filter used in the dynamic voltage restorer, Power Delivery, IEEE Transactions on, vol. 17, no. 3, (2002) 857-864.

DOI: 10.1109/tpwrd.2002.1022815

Google Scholar

[40] R. Omar, N. A. Rahim, Power quality improvement in low voltage distribution system using Dynamic Voltage Restorer (DVR), Industrial Electronics and Applications (ICIEA), 2010 the 5th IEEE Conference on, vol., no., (2010) 973-978.

DOI: 10.1109/iciea.2010.5515734

Google Scholar

[41] M. F. Kangarlu, S. H. Hosseini, E. Babaei, A. Khoshkbar Sadigh, Transformerless DVR topology based on multilevel inverter with reduced number of switches, Power Electronic & Drive Systems & Technologies Conference (PEDSTC), 2010 1st , vol., no., (2010).

DOI: 10.1109/pedstc.2010.5471786

Google Scholar

[42] P. Roncero-Sanchez, E. Acha, Dynamic Voltage Restorer Based on Flying Capacitor Multilevel Converters Operated by Repetitive Control, Power Delivery, IEEE Transactions on, vol. 24, no. 2, (2009) 951-960.

DOI: 10.1109/tpwrd.2008.2005885

Google Scholar

[43] E. Babaei, M. F. Kangarlu, M. Sabahi, Dynamic voltage restorer based on multilevel inverter with adjustable dc-link voltage, Power Electronics, IET, vol. 7, no. 3, (2014) 576-590.

DOI: 10.1049/iet-pel.2013.0179

Google Scholar

[44] A. Mahmoud, Y. El-Gammal, Amr Y. Abou-Ghazala and Tarek I. El-Shennawy, Dynamic Voltage Restorer (DVR) for Voltage Sag Mitigation, International Journal on Electrical Engineering and Informatics, vol. 3, no. 1, (2011) 1-11.

DOI: 10.15676/ijeei.2011.3.1.1

Google Scholar

[45] H. K. Al-Hadidi, A. M. Gole, JD. A. acobson, A Novel Configuration for a Cascade_Inverter-Based Dynamic Voltage Restorer with Reduced Energy Storage Requirements, Power Delivery, IEEE Transactions on, vol. 23, no. 2, (2008) 881-888.

DOI: 10.1109/tpwrd.2007.915989

Google Scholar

[46] J. G. Nielsen, F. Blaabjerg, A detailed comparison of system topologies for dynamic voltage restorers, Industry Applications, IEEE Transactions on, vol. 41, no. 5, (2005) 1272-1280.

DOI: 10.1109/tia.2005.855045

Google Scholar

[47] M. F. Kangarlu, E. Babaei, Determination of the transformer turns ratio in a DVR to reduce the switches voltage rating, Power Electronics and Drive Systems Technology (PEDSTC), 2012 3rd, vol., no., (2012) 315-318.

DOI: 10.1109/pedstc.2012.6183347

Google Scholar

[48] V. K. Ramachandaramurthy, C. Fitzer, A. Arulampalam, C. Zhan, M. Barnes, N. Jenkins, Control of a battery supported dynamic voltage restorer, Generation, Transmission and Distribution, IEE Proceedings- , vol. 149, no. 5, (2002) 533-542.

DOI: 10.1049/ip-gtd:20020658

Google Scholar

[49] E. Babaei, M. K. Farhadi, Cross-phase voltage sag compensator for threephase distribution systems., International Journal of Electrical Power & Energy Systems, vol. 51, (2013) 119-126.

DOI: 10.1016/j.ijepes.2013.02.016

Google Scholar

[50] C. Zhan, M. Barnes, V.K. Ramachandarmurthy, N. Jenkins, Dynamic Voltage Restorer with a battery Energy Storage for Voltage Dip Mitigation, Eighth International Conference on Power Electronics and Variable Speed Drives. 18-19 (2000) 360-365.

DOI: 10.1049/cp:20000273

Google Scholar

[51] R. Omar, N. Rahim, M. Sulaiman, Dynamic Voltage Restorer Application for Power Quality Improvement in Electrical Distribution System: An Overview, Australian Journal of Basic and Applied Sciences, vol. 5, no. 12, (2011) 379-396.

Google Scholar

[52] M. Vilathgamuwa, H. M. Wijekoon, Mitigating Zero Sequence Effects in Dynamic Voltage Restorers, Power Electronics Specialists Conference, 2007. PESC 2007. IEEE, vol., no., (2007) 3079- 3085.

DOI: 10.1109/pesc.2007.4342517

Google Scholar

[53] J. Praveen, B. P. Muni, S. Venkateshwarlu, H. V. Makthal, Review of dynamic voltage restorer for power quality Improvement, Industrial Electronics Society, 2004. IECON 2004. 30th Annual Conference of IEEE, vol. 1, no., (2004) 749-754.

DOI: 10.1109/iecon.2004.1433408

Google Scholar

[54] Y. W. Li, D. M. Vilathgamuwa, F. Blaabjerg, P. C. Loh, A Robust Control Scheme for Medium-Voltage-Level DVR Implementation, Industrial Electronics, IEEE Transactions on, vol. 54, no. 4, (2007) 2249-2261.

DOI: 10.1109/tie.2007.894771

Google Scholar

[55] J.G. Nielsen, F. Blaabjerg, N. Mohan, Control strategies for dynamic voltage restorer compensating voltage sags with phase jump, IEEE Applied Power Electronics Conference and Exposition. 2 (2001) 1267-1273.

DOI: 10.1109/apec.2001.912528

Google Scholar

[56] H. Ghosh, P. K. Shah, G. K. Panda, Design and Simulation of a Novel Self Supported Dynamic Voltage Restorer (DVR) for Power Quality Improvement, International Journal of Scientific & Engineering Research, vol. 3, issue 6, (2012) 1-6.

Google Scholar

[57] R. McHattie, Dynamic voltage restorer the customers's perspective, Dynamic Voltage Restorers -Replacing Those Missing Cycles (Digest No. 1998/189), IEE Half Day Colloquium on , vol., no., (1998) 1/1, 1/5.

DOI: 10.1049/ic:19980008

Google Scholar

[58] M. A. Bhaskar, S. S. Dash, C. Subramani, M. J. Kumar, P. R. Giresh, Kumar, M.V., Voltage Quality Improvement Using DVR, Recent Trends in Information, Telecommunication and Computing (ITC), 2010 International Conference on , vol., no., (2010).

DOI: 10.1109/itc.2010.80

Google Scholar

[59] P. Vasudevanaidu, M. Tech, Y. Narendra Kumar, A new simple modeling and analysis of custom power controllers, " Power Systems, 2009. ICPS , 09. International Conference on, vol., no., (2009) 1, 6, 27-29.

DOI: 10.1109/icpws.2009.5442766

Google Scholar

[60] M.M. Bhanoo, Static transfer switch: advances in high speed solid-state transfer switches for critical power quality and reliability applications, Textile, Fiber and Film Industry Technical Conference, 1998 IEEE Annual , vol., no., (1998).

DOI: 10.1109/texcon.1998.679225

Google Scholar

[61] M. N. Tandjaoui, C. Benachaiba, O. Abdelkhalek, M. L. Doumbia, Y. Mouloudi, Sensitive loads voltage improvement using Dynamic Voltage Restorer, Electrical Engineering and Informatics (ICEEI), 2011 International Conference on , vol., no., (2011).

DOI: 10.1109/iceei.2011.6021679

Google Scholar

[62] V. K Ramachandaramurthy, A. Arulampalam, C. Fitzer, C. Zhan, M. Barnes, N. Jenkins, Supervisory control of dynamic voltage restorers, Generation, Transmission and Distribution, IEE Proceedings- , vol. 151, no. 4, (2004) 509, 516.

DOI: 10.1049/ip-gtd:20040506

Google Scholar

[63] V.K. Ramachandaramurthy, A. Arulampalam, C. Fitzer, C. Zhan, M. Barnes, N. Jenkins, Supervisory control of dynamic voltage restorer, Generation Transmission and Distribution, IEE Proceedings. 151 (4) (2011) 509, 516.

DOI: 10.1049/ip-gtd:20040506

Google Scholar

[64] C. Fitzer, A. Arulampalam, M. Barnes, Zurowski, Rainer, Migation of saturation in dynamic voltage restorer connection transformer, Power Electronics, IEEE Transactions. 17 (6) (2002) 1058-1066.

DOI: 10.1109/tpel.2002.805584

Google Scholar

[65] C. Zhan, V.K. Ramachandaramurthy, A. Arulampalam, C. Fitzzer, M. Barnes, N. Jenkins, Control of a battery supported dynamic voltage restorer, IEE proceedings on Transmission and Distribution, 149(5) (2002) 533-542.

DOI: 10.1049/ip-gtd:20020658

Google Scholar

[66] P. Margo, M.P. Heri, M. Ashari, T. Hiyama, Balanced voltage sag correction using dynamic voltage restorer based fuzzy polar controller, Proceedings of the Second International Conference on Innovative Computing, Information and Control. (2007).

DOI: 10.1109/icicic.2007.194

Google Scholar

[67] J.G. Nielsen, F. Blaabjerg, N. Mohan, Control strategies for dynamic voltage restorer compensating voltage sags with phase jump, Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual IEEE, vol. 2, (2001).

DOI: 10.1109/apec.2001.912528

Google Scholar

[68] A. K Sadigh, K. M. Smedley, Review of voltage compensation methods in dynamic voltage restorer (DVR), Power and Energy Society General Meeting, 2012 IEEE , vol. 1, no. 8, (2012).

DOI: 10.1109/pesgm.2012.6345153

Google Scholar

[69] S. H. Hosseini, M. R. Banaei, A new minimal energy control of the DC link energy in four-wire dynamic voltage restorer, Industrial Electronics Society, 2004. IECON 2004. 30th Annual Conference of IEEE, vol. 3, no., (2004) 3048-3053.

DOI: 10.1109/iecon.2004.1432298

Google Scholar

[70] M.R. Banaei, A. Nahavandi, S. H. Hosseini, Investigation of multi-functional DVR to improve power quality characteristic, Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, 2009. ECTI-CON 2009. 6th International Conference on, vol. 01, no., (2009).

DOI: 10.1109/ecticon.2009.5136984

Google Scholar

[71] Abdollahzadeh, Hamed, Mostafa Jazaeri, and Arash Tavighi. A new fast-converged estimation approach for Dynamic Voltage Restorer (DVR) to compensate voltage sags in waveform distortion conditions., International Journal of Electrical Power & Energy Systems vol. 54, (2014).

DOI: 10.1016/j.ijepes.2013.08.012

Google Scholar

[72] C.S. Chang, Zhemin Yu, Distributed Mitigation of Voltage Sag by Optimal Placement of Series Compensation Devices Based on Stochastic Assessment, IEEE transactions on Power Systems. 19(2) (2004) 788-795.

DOI: 10.1109/tpwrs.2004.825826

Google Scholar

[73] P. Daehler, R. Molter, 2000. Requirements and Solutions for Dynamic Voltage Restorer, A Case Study. IEEE Power Engineering Society Winter Meeting, 4 (2000) 2881-2885.

DOI: 10.1109/pesw.2000.847342

Google Scholar

[74] H. Ezoji, A. Sheikholeslami, M. Tabasi, M.M. Saeednia, Simulation of Dynamic Voltage Restorer Using Hysteresis Voltage Control, European Journal of Scientific Research (EJSR). 27(1) (2009) 152-166.

Google Scholar

[75] M. Vilathgamuwa, A. AD. Ranjithperera, S.S. Choi, Performance improvement of the dynamic voltage restorer with closed-loop load voltage and current-mode control, Power Electronics. 17(9) (2002) 824-834.

DOI: 10.1109/tpel.2002.802189

Google Scholar

[76] Y.H. Zhang, D.M. Viathgamuwa, Choi S S, An experimental investigation of dynamic voltage restorer (DVR), Proceedings of Power Engineering Society Winter Meeting, Singapore, Piscataway, NJ, USA, IEEE, (2000) 2745-2750.

DOI: 10.1109/pesw.2000.847317

Google Scholar

[77] H. Han, Y. Chao, H. Yingduo, The simulation and experiment of dynamic voltage restorer control strategy, Power System Technology, (2002).

Google Scholar

[78] Z. Xuedong, Z. Zhiyong, M. Youjie, Research on dynamic voltage restorer with double closed-loop control strategy, Power Electronics. (2007) 34-36.

Google Scholar

[79] G. Nielsenj, M. Newman, H. Nielsen, Control and testing of a dynamic voltage restorer (DVR) at medium voltage level, IEEE Trans on Power Electronics. (2004) 806-813.

DOI: 10.1109/tpel.2004.826504

Google Scholar

[80] N.H. Woodley, L. Morgan, A. Sundaram, Experience with an Inverter-Based Dynamic Voltage Restorer, IEEE Transactions on Power Delivery, 14 (1999) 1181-1186.

DOI: 10.1109/61.772390

Google Scholar

[81] Sngek, S.S. Choi, M. Vilathgamuwa, Analysis of series compensation and DC-link voltage controls of a transformer less self-charging dynamic voltage restorer, IEEE Trans on Power Delivery. 19(3) (2004) 1511-1518.

DOI: 10.1109/tpwrd.2004.829866

Google Scholar

[82] F. Jurado M. Valverde, J. Carpi, Voltage Sag Correction by Dynamic Voltage Restorer Based on Fuzzy Logic Control, IEEE. (2003) 421-424.

DOI: 10.1109/ccece.2003.1226430

Google Scholar

[83] Wang Jing; Xu Aiqin; Shen Yueyue, A survey on control strategies of dynamic voltage restorer, Harmonics and Quality of Power, 2008. ICHQP 2008. 13th International Conference on, vol., no., (2008) 1-5.

DOI: 10.1109/ichqp.2008.4668845

Google Scholar

[84] F. Jurado, Neural network control for dynamic voltage restorer, Industrial Electronics, IEEE Transactions on, vol. 51, no. 3, (2004) 727-729.

DOI: 10.1109/tie.2004.825203

Google Scholar

[85] L.A. Zadeh, Fuzzy sets Inform Control, (1965) 338-353.

Google Scholar

[86] K.Q. Bayindir, A. Teke, M. Tumay, A robust control of dynamic voltage restorer using fuzzy logic, " Electrical Machines and Power Electronics, 2007. ACEMP , 07. International Aegean Conference on, vol., no., (2007) 55-60.

DOI: 10.1109/acemp.2007.4510483

Google Scholar

[87] C. H. Srisailam, A. Sreenivas, Mitigation of voltage sags/swells by dynamic voltage restorer using PI and fuzzy logic controller., International Journal of Engineering Research and Applications, vol. 2, no. 4, (2012) 1733-1737.

DOI: 10.22214/ijraset.2018.3577

Google Scholar

[88] C. K. Sundarabalan, K. Selvi. Compensation of voltage disturbances using PEMFC supported Dynamic Voltage Restorer., International Journal of Electrical Power & Energy Systems, vol. 71, (2015) 77–92.

DOI: 10.1016/j.ijepes.2015.02.032

Google Scholar

[89] S.J. Lee, H. Kim, S.K. Sul, A novel control algorithm for static series compensators by use of PQR instantaneous power theory, IEEE Trans on Power Electronics. (2004) 814-827.

DOI: 10.1109/tpel.2004.826499

Google Scholar

[90] H.M. Wijekoon, D.M. Vilathgamuwa, S.S. Choi, Interline dynamic voltage restorer: an economical way to improve interline power quality, Generation, Transmission and Distribution, IEE Proceedings- , vol. 150, no. 5, (2003) 513-520.

DOI: 10.1049/ip-gtd:20030800

Google Scholar

[91] M. Moradlou, H. R. Karshenas, Design Strategy for Optimum Rating Selection of Interline DVR, Power Delivery, IEEE Transactions on, vol. 26, no. 1, (2011) 242-249.

DOI: 10.1109/tpwrd.2010.2071403

Google Scholar

[92] H. R. Karshenas, H.R.; M. Moradlou, M., Design strategy for optimum rating selection in interline DVR, Electrical and Computer Engineering, 2008. CCECE 2008. Canadian Conference on, vol., no., (2008) 1919-(1924).

DOI: 10.1109/ccece.2008.4564878

Google Scholar

[93] G. J. S. Dhas, T. R. D. Prakash, A novel approach for voltage sag mitigation using facts device interline dynamic voltage restorer, Electronics Computer Technology (ICECT), 2011 3rd International Conference on , vol. 4, no., (2011).

DOI: 10.1109/icectech.2011.5941852

Google Scholar

[94] R. P. Usha, R. Sudha, S. Rama Reddy, Voltage sag/swell compensation in an interline dynamic voltage restorer., In Emerging Trends in Electrical and Computer Technology (ICETECT), 2011 International Conference on, (2011) 309-314.

DOI: 10.1109/icetect.2011.5760134

Google Scholar

[95] A. Elserougi, A. S. Abdel-Khalik, S. Ahmed, A. Massoud, Active and reactive power management of photovoltaic-based interline dynamic voltage restorer in low voltage distribution networks, Energy Conversion Congress and Exposition (ECCE), 2012 IEEE, vol., no., (2012).

DOI: 10.1109/ecce.2012.6342355

Google Scholar

[96] A. Hossam-Eldin, A. Elserougi, Renewable energy fed interline DVR for voltage sag mitigation in distribution grids, Electricity Distribution (CIRED 2013), 22nd International Conference and Exhibition on, vol., no., (2013) 1, 4.

DOI: 10.1049/cp.2013.0540

Google Scholar

[97] D. M. Vilathgamuwa, H. M. Wijekoon, S. S. Choi, Interline dynamic voltage restorer: a novel and economical approach for multiline power quality compensation, Industry Applications, IEEE Transactions on, vol. 40, no. 6, (2004) 1678, -685.

DOI: 10.1109/tia.2004.836314

Google Scholar