Application of Dynamic Voltage Restorer for Power Quality Improvement in Low Voltage Electrical Power Distribution Network: An Overview
Abstract:
Dynamic Voltage Restorer (DVR) is a series connected power electronics based custom power device that is used to improve voltage disturbances in low voltage electrical power distribution network. Power quality requirement is one of the most important concerns for power system. The parts of the DVR is made up of voltage source inverter, injection/booster transformer, a harmonic filter, an energy storage device and a bypass switch. The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control. This paper presents a review of the researches on the dynamic voltage restorer application for power quality improvement in low voltage electrical power distribution networks. It describes power quality issues, principle of operation of DVR, basic components of DVR, DVRs control topologies in distribution network, DVR control strategies and compensation techniques.
Info:
Periodical:
Pages:
142-156
Citation:
Online since:
January 2017
Authors:
Price:
Сopyright:
© 2017 Trans Tech Publications Ltd. All Rights Reserved
Citation:
* - Corresponding Author
[1] H. De Keulenaer, The hidden cost of poor power quality, European copper institute. (2003).
[2] S.W. Middlekauff, E.R. Collins Jr, System and Customer Impact Considerations for Series Custom Power Devices, IEEE Transactions on Power Delivery. 13(1) (1998) 278-282.
DOI: 10.1109/61.660890
[3] P. Roncero-Sanchez, E. Acha, Dynamic voltage restorer based on flying capacitor multilevel converters operated by repetitive control, Power Delivery, IEEE Transactions on. 24(2) (2009) 951-960.
[4] Rosli Omar, et al, Dynamic Voltage Restorer Application for Power Quality Improvement in Electrical Distribution System, An Overview. Australian Journal of Basic and Applied Sciences. (2011).
[5] M.J. Newman, D.G. Holmes, J.G. Nielsen, F. Blaabjerg, A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level, Industry Applications, IEEE Transactions. 41 (2003) 1744-1753.
[6] F.A. L Jowder, Design and analysis of dynamic voltage restorer for deep voltage sag and harmonic compensation, Generation, Transmission & Distribution. 3 (, 2009) 547-560.
[7] E. Babaei, M. F. Kangarlu, Sensitive load voltage compensation against voltage sags/swells and harmonics in the grid voltage and limit downstream fault currents using DVR, Electric Power Systems Research. 83(1) (2012) 80-90.
[8] Y.W. Li, M. Vilathgamuwa, D.P. Chiang Loh, F. Blaabjerg, A dual-functional medium voltage level DVR to limit downstream fault currents", Power Electronics, IEEE Transactions. 22 (2007) 1330-1340.
[9] M. H. Bollen, Understanding power quality Problems, IEEE press New York, USA, (2000).
[10] A. Ghosh, et al, Design of a capacitor-supported dynamic voltage restorer (DVR) for unbalanced and distorted loads, Power Delivery, IEEE Transactions on. 19(1) (2004) 405-413.
[11] S.S. Choi, B.H. Li, D.M. Vilathgamuwa, A comparative study of inverter- and line-side filtering schemes in the dynamic voltage restorer, IEEE Power Engineering Society Winter Meeting. 4 (2000) 2967-2972.
[12] J. G. Nielsen, F. Blaabjerg, A detailed comparison of system topologies for dynamic voltage restorers, Industry Applications, IEEE Transactions on. 41(5) (2005) 1272-1280.
[13] R. C. Dugan, M. F. McGranaghan, S. Santoso, H. Wayne Beaty: , Electrical Power Systems Quality second edition, McGraw-Hill, New York, (2002).
[14] IEEE Standard 100-1992, IEEE Standard Dictionary of Electrical and Electronic Terms.
[15] IEC 61000-4-30 77A/356/CDV, Power Quality Measurement Methods. (2001).
[16] C. Benachaiba, B. Ferdi, Power Quality Improvement Using DVR, American Journal of Applied Sciences, vol. 6 issue 3, (2009) 396-400.
[17] R. Omar, N.A. Rahim, Modeling and simulation for voltage sags/swells mitigation using dynamic voltage restorer (DVR), "Power Engineering Conference, 2008. AUPEC , 08. Australasian Universities, vol. 1, no. 5, (2008) 14-17.
[18] M.H.J. Bollen, Understanding power quality problems, Vol. 3. New York: IEEE press, (2000).
[19] A. Pakharia, M. Gupta, Dynamic Voltage Restorer for Compensation of Voltage Sag and Swell: A Literature Review, International Journal of Advance in Engineering & Technology, vol 4, issue 1, (2012) 347-355.
DOI: 10.31142/ijtsrd23740
[20] J. Stones, & A. Collinson, Power quality, Power Eng. Journal, vol. 15, no. 2, (2001) 58-64.
[21] M. H. J Bollen, What is power quality?, Electric Power Systems Research, vol. 66, no. 1, (2003) 5-14.
[22] A. El Mofty, K. Youssef, Industrial power quality problems, Electricity Distribution, Part 1: Contributions. CIRED. 16th International Conference and Exhibition on (IEE Conf. Publ No. 482), vol. 2, no., 5 (2001).
DOI: 10.1049/cp:20010757
[23] W.E. Reid, Power quality issues-standards and guidelines, Industry Applications, IEEE Transactions on, vol. 32, no. 3, (1996) 625-632.
DOI: 10.1109/28.502175
[24] S.J. Lee, H. Kim, S.K. Sul, A novel control algorithm for static series compensators by use of PQR instantaneous power theory, IEEE Trans on Power Electronics. 19(3) (2004) 814-827.
[25] S.S. Mahesh, M.K. Mishra, B.K. Kumar, V. Jayashankar, Rating and design issues of DVR injection transformer", Applied Power Electronics Conference and Exposition. (2008) 449-455.
[26] P.K.W. Chan, K.K.S. Leung, H.S.H. Chung, S.Y.R. Hui, Boundary controller for dynamic voltage restorers to achieve fast dynamic response, Applied Power Electronics Conference and Exposition. (2006) 6.
[27] A. Ghosh, G. Ledwich, Compensation of distribution system voltage using DVR, Power Delivery, IEEE Transactions on, vol. 17, no. 4, (2002) 1030-1036.
[28] C.J. Posada, J.M. Ramirez, R.E. Correa, Voltage compensation for common disturbances at the distribution level, Innovative Smart Grid Technologies (ISGT Latin America), IEEE PES Conference on, vol., no16, (2011) 19-21.
[29] N.H. Woodley, L. Morgan, A. Sundaram, Experience with an inverter-based dynamic voltage restorer, Power Delivery, IEEE Transactions on, vol. 14, no. 3, (1999).
DOI: 10.1109/61.772390
[30] R. Omar, N. Rahim, & M. Sulaiman, Dynamic Voltage Restorer Application for Power Quality Improvement in Electrical Distribution System: An Overview, Australian Journal of Basic and Applied Sciences, vol. 5, no. 12, (2011) 379-396.
[31] M. Vilathgamuwa, H. W. Wijekoon, Mitigating Zero Sequence Effects in Dynamic Voltage Restorers, Power Electronics Specialists Conference, PESC 2007. IEEE, vol., no., pp.3079-3085, 17-21 June (2007).
[32] C. Zhan, V.K. Ramachandaramurthy, A. Arulampalam, C. Fitzer, S. Kromlidis,M. Barnes, N. Jenkins, Dynamic voltage restorer based on voltage space vector PWM control, Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual IEEE, vol. 2, (2001).
[33] C. Zhan, M. Barnes, V. K Ramachandaramurthy, N. Jenkins, Dynamic voltage restorer with battery energy storage for voltage dip mitigation, Power Electronics and Variable Speed Drives, 2000. Eighth International Conference on (IEE Conf. Publ. No. 475), vol., (2000).
DOI: 10.1049/cp:20000273
[34] B. H Li, S.S. Choi, D. M. Vilathgamuwa, On the injection transformer used in the dynamic voltage restorer, Power System Technology, 2000. Proceedings. PowerCon 2000. International Conference on, vol. 2, (2000) 941-946.
[35] S. S. Mahesh, M. K. Mishra, B. K. Kumar, V. Jayashankar, Rating and design issues of DVR injection transformer, Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE, vol., no., (2008) 449-455.
[36] H. Kim, J. Kim, S. Sul, A design consideration of output filters for dynamic voltage restorers, Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual, vol. 6, no., (2004).
[37] S.S. Choi, B. H. Li, D. M. Vilathgamuwa, A comparative study of inverter and line-side filtering schemes in the dynamic voltage restorer, Power Engineering Society Winter Meeting, 2000. IEEE, vol. 4, no., (2000) 2967-2972.
[38] S. S. Choi, B.H. Li, D.M. Vilathgamuwa, Design and Analysis of the Inverter-Side Filter Used in the Dynamic Voltage Restorer, Power Engineering Review, IEEE, vol. 22, no. 4, (2002) 80-80.
[39] S.S. Choi, B. H. Li, D. M. Vilathgamuwa, Design and analysis of the inverter-side filter used in the dynamic voltage restorer, Power Delivery, IEEE Transactions on, vol. 17, no. 3, (2002) 857-864.
[40] R. Omar, N. A. Rahim, Power quality improvement in low voltage distribution system using Dynamic Voltage Restorer (DVR), Industrial Electronics and Applications (ICIEA), 2010 the 5th IEEE Conference on, vol., no., (2010) 973-978.
[41] M. F. Kangarlu, S. H. Hosseini, E. Babaei, A. Khoshkbar Sadigh, Transformerless DVR topology based on multilevel inverter with reduced number of switches, Power Electronic & Drive Systems & Technologies Conference (PEDSTC), 2010 1st , vol., no., (2010).
[42] P. Roncero-Sanchez, E. Acha, Dynamic Voltage Restorer Based on Flying Capacitor Multilevel Converters Operated by Repetitive Control, Power Delivery, IEEE Transactions on, vol. 24, no. 2, (2009) 951-960.
[43] E. Babaei, M. F. Kangarlu, M. Sabahi, Dynamic voltage restorer based on multilevel inverter with adjustable dc-link voltage, Power Electronics, IET, vol. 7, no. 3, (2014) 576-590.
[44] A. Mahmoud, Y. El-Gammal, Amr Y. Abou-Ghazala and Tarek I. El-Shennawy, Dynamic Voltage Restorer (DVR) for Voltage Sag Mitigation, International Journal on Electrical Engineering and Informatics, vol. 3, no. 1, (2011) 1-11.
[45] H. K. Al-Hadidi, A. M. Gole, JD. A. acobson, A Novel Configuration for a Cascade_Inverter-Based Dynamic Voltage Restorer with Reduced Energy Storage Requirements, Power Delivery, IEEE Transactions on, vol. 23, no. 2, (2008) 881-888.
[46] J. G. Nielsen, F. Blaabjerg, A detailed comparison of system topologies for dynamic voltage restorers, Industry Applications, IEEE Transactions on, vol. 41, no. 5, (2005) 1272-1280.
[47] M. F. Kangarlu, E. Babaei, Determination of the transformer turns ratio in a DVR to reduce the switches voltage rating, Power Electronics and Drive Systems Technology (PEDSTC), 2012 3rd, vol., no., (2012) 315-318.
[48] V. K. Ramachandaramurthy, C. Fitzer, A. Arulampalam, C. Zhan, M. Barnes, N. Jenkins, Control of a battery supported dynamic voltage restorer, Generation, Transmission and Distribution, IEE Proceedings- , vol. 149, no. 5, (2002) 533-542.
[49] E. Babaei, M. K. Farhadi, Cross-phase voltage sag compensator for threephase distribution systems., International Journal of Electrical Power & Energy Systems, vol. 51, (2013) 119-126.
[50] C. Zhan, M. Barnes, V.K. Ramachandarmurthy, N. Jenkins, Dynamic Voltage Restorer with a battery Energy Storage for Voltage Dip Mitigation, Eighth International Conference on Power Electronics and Variable Speed Drives. 18-19 (2000) 360-365.
DOI: 10.1049/cp:20000273
[51] R. Omar, N. Rahim, M. Sulaiman, Dynamic Voltage Restorer Application for Power Quality Improvement in Electrical Distribution System: An Overview, Australian Journal of Basic and Applied Sciences, vol. 5, no. 12, (2011) 379-396.
[52] M. Vilathgamuwa, H. M. Wijekoon, Mitigating Zero Sequence Effects in Dynamic Voltage Restorers, Power Electronics Specialists Conference, 2007. PESC 2007. IEEE, vol., no., (2007) 3079- 3085.
[53] J. Praveen, B. P. Muni, S. Venkateshwarlu, H. V. Makthal, Review of dynamic voltage restorer for power quality Improvement, Industrial Electronics Society, 2004. IECON 2004. 30th Annual Conference of IEEE, vol. 1, no., (2004) 749-754.
[54] Y. W. Li, D. M. Vilathgamuwa, F. Blaabjerg, P. C. Loh, A Robust Control Scheme for Medium-Voltage-Level DVR Implementation, Industrial Electronics, IEEE Transactions on, vol. 54, no. 4, (2007) 2249-2261.
[55] J.G. Nielsen, F. Blaabjerg, N. Mohan, Control strategies for dynamic voltage restorer compensating voltage sags with phase jump, IEEE Applied Power Electronics Conference and Exposition. 2 (2001) 1267-1273.
[56] H. Ghosh, P. K. Shah, G. K. Panda, Design and Simulation of a Novel Self Supported Dynamic Voltage Restorer (DVR) for Power Quality Improvement, International Journal of Scientific & Engineering Research, vol. 3, issue 6, (2012) 1-6.
[57] R. McHattie, Dynamic voltage restorer the customers's perspective, Dynamic Voltage Restorers -Replacing Those Missing Cycles (Digest No. 1998/189), IEE Half Day Colloquium on , vol., no., (1998) 1/1, 1/5.
DOI: 10.1049/ic:19980008
[58] M. A. Bhaskar, S. S. Dash, C. Subramani, M. J. Kumar, P. R. Giresh, Kumar, M.V., Voltage Quality Improvement Using DVR, Recent Trends in Information, Telecommunication and Computing (ITC), 2010 International Conference on , vol., no., (2010).
DOI: 10.1109/itc.2010.80
[59] P. Vasudevanaidu, M. Tech, Y. Narendra Kumar, A new simple modeling and analysis of custom power controllers, " Power Systems, 2009. ICPS , 09. International Conference on, vol., no., (2009) 1, 6, 27-29.
[60] M.M. Bhanoo, Static transfer switch: advances in high speed solid-state transfer switches for critical power quality and reliability applications, Textile, Fiber and Film Industry Technical Conference, 1998 IEEE Annual , vol., no., (1998).
[61] M. N. Tandjaoui, C. Benachaiba, O. Abdelkhalek, M. L. Doumbia, Y. Mouloudi, Sensitive loads voltage improvement using Dynamic Voltage Restorer, Electrical Engineering and Informatics (ICEEI), 2011 International Conference on , vol., no., (2011).
[62] V. K Ramachandaramurthy, A. Arulampalam, C. Fitzer, C. Zhan, M. Barnes, N. Jenkins, Supervisory control of dynamic voltage restorers, Generation, Transmission and Distribution, IEE Proceedings- , vol. 151, no. 4, (2004) 509, 516.
[63] V.K. Ramachandaramurthy, A. Arulampalam, C. Fitzer, C. Zhan, M. Barnes, N. Jenkins, Supervisory control of dynamic voltage restorer, Generation Transmission and Distribution, IEE Proceedings. 151 (4) (2011) 509, 516.
[64] C. Fitzer, A. Arulampalam, M. Barnes, Zurowski, Rainer, Migation of saturation in dynamic voltage restorer connection transformer, Power Electronics, IEEE Transactions. 17 (6) (2002) 1058-1066.
[65] C. Zhan, V.K. Ramachandaramurthy, A. Arulampalam, C. Fitzzer, M. Barnes, N. Jenkins, Control of a battery supported dynamic voltage restorer, IEE proceedings on Transmission and Distribution, 149(5) (2002) 533-542.
[66] P. Margo, M.P. Heri, M. Ashari, T. Hiyama, Balanced voltage sag correction using dynamic voltage restorer based fuzzy polar controller, Proceedings of the Second International Conference on Innovative Computing, Information and Control. (2007).
[67] J.G. Nielsen, F. Blaabjerg, N. Mohan, Control strategies for dynamic voltage restorer compensating voltage sags with phase jump, Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual IEEE, vol. 2, (2001).
[68] A. K Sadigh, K. M. Smedley, Review of voltage compensation methods in dynamic voltage restorer (DVR), Power and Energy Society General Meeting, 2012 IEEE , vol. 1, no. 8, (2012).
[69] S. H. Hosseini, M. R. Banaei, A new minimal energy control of the DC link energy in four-wire dynamic voltage restorer, Industrial Electronics Society, 2004. IECON 2004. 30th Annual Conference of IEEE, vol. 3, no., (2004) 3048-3053.
[70] M.R. Banaei, A. Nahavandi, S. H. Hosseini, Investigation of multi-functional DVR to improve power quality characteristic, Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, 2009. ECTI-CON 2009. 6th International Conference on, vol. 01, no., (2009).
[71] Abdollahzadeh, Hamed, Mostafa Jazaeri, and Arash Tavighi. A new fast-converged estimation approach for Dynamic Voltage Restorer (DVR) to compensate voltage sags in waveform distortion conditions., International Journal of Electrical Power & Energy Systems vol. 54, (2014).
[72] C.S. Chang, Zhemin Yu, Distributed Mitigation of Voltage Sag by Optimal Placement of Series Compensation Devices Based on Stochastic Assessment, IEEE transactions on Power Systems. 19(2) (2004) 788-795.
[73] P. Daehler, R. Molter, 2000. Requirements and Solutions for Dynamic Voltage Restorer, A Case Study. IEEE Power Engineering Society Winter Meeting, 4 (2000) 2881-2885.
[74] H. Ezoji, A. Sheikholeslami, M. Tabasi, M.M. Saeednia, Simulation of Dynamic Voltage Restorer Using Hysteresis Voltage Control, European Journal of Scientific Research (EJSR). 27(1) (2009) 152-166.
[75] M. Vilathgamuwa, A. AD. Ranjithperera, S.S. Choi, Performance improvement of the dynamic voltage restorer with closed-loop load voltage and current-mode control, Power Electronics. 17(9) (2002) 824-834.
[76] Y.H. Zhang, D.M. Viathgamuwa, Choi S S, An experimental investigation of dynamic voltage restorer (DVR), Proceedings of Power Engineering Society Winter Meeting, Singapore, Piscataway, NJ, USA, IEEE, (2000) 2745-2750.
[77] H. Han, Y. Chao, H. Yingduo, The simulation and experiment of dynamic voltage restorer control strategy, Power System Technology, (2002).
[78] Z. Xuedong, Z. Zhiyong, M. Youjie, Research on dynamic voltage restorer with double closed-loop control strategy, Power Electronics. (2007) 34-36.
[79] G. Nielsenj, M. Newman, H. Nielsen, Control and testing of a dynamic voltage restorer (DVR) at medium voltage level, IEEE Trans on Power Electronics. (2004) 806-813.
[80] N.H. Woodley, L. Morgan, A. Sundaram, Experience with an Inverter-Based Dynamic Voltage Restorer, IEEE Transactions on Power Delivery, 14 (1999) 1181-1186.
DOI: 10.1109/61.772390
[81] Sngek, S.S. Choi, M. Vilathgamuwa, Analysis of series compensation and DC-link voltage controls of a transformer less self-charging dynamic voltage restorer, IEEE Trans on Power Delivery. 19(3) (2004) 1511-1518.
[82] F. Jurado M. Valverde, J. Carpi, Voltage Sag Correction by Dynamic Voltage Restorer Based on Fuzzy Logic Control, IEEE. (2003) 421-424.
[83] Wang Jing; Xu Aiqin; Shen Yueyue, A survey on control strategies of dynamic voltage restorer, Harmonics and Quality of Power, 2008. ICHQP 2008. 13th International Conference on, vol., no., (2008) 1-5.
[84] F. Jurado, Neural network control for dynamic voltage restorer, Industrial Electronics, IEEE Transactions on, vol. 51, no. 3, (2004) 727-729.
[85] L.A. Zadeh, Fuzzy sets Inform Control, (1965) 338-353.
[86] K.Q. Bayindir, A. Teke, M. Tumay, A robust control of dynamic voltage restorer using fuzzy logic, " Electrical Machines and Power Electronics, 2007. ACEMP , 07. International Aegean Conference on, vol., no., (2007) 55-60.
[87] C. H. Srisailam, A. Sreenivas, Mitigation of voltage sags/swells by dynamic voltage restorer using PI and fuzzy logic controller., International Journal of Engineering Research and Applications, vol. 2, no. 4, (2012) 1733-1737.
[88] C. K. Sundarabalan, K. Selvi. Compensation of voltage disturbances using PEMFC supported Dynamic Voltage Restorer., International Journal of Electrical Power & Energy Systems, vol. 71, (2015) 77–92.
[89] S.J. Lee, H. Kim, S.K. Sul, A novel control algorithm for static series compensators by use of PQR instantaneous power theory, IEEE Trans on Power Electronics. (2004) 814-827.
[90] H.M. Wijekoon, D.M. Vilathgamuwa, S.S. Choi, Interline dynamic voltage restorer: an economical way to improve interline power quality, Generation, Transmission and Distribution, IEE Proceedings- , vol. 150, no. 5, (2003) 513-520.
[91] M. Moradlou, H. R. Karshenas, Design Strategy for Optimum Rating Selection of Interline DVR, Power Delivery, IEEE Transactions on, vol. 26, no. 1, (2011) 242-249.
[92] H. R. Karshenas, H.R.; M. Moradlou, M., Design strategy for optimum rating selection in interline DVR, Electrical and Computer Engineering, 2008. CCECE 2008. Canadian Conference on, vol., no., (2008) 1919-(1924).
[93] G. J. S. Dhas, T. R. D. Prakash, A novel approach for voltage sag mitigation using facts device interline dynamic voltage restorer, Electronics Computer Technology (ICECT), 2011 3rd International Conference on , vol. 4, no., (2011).
[94] R. P. Usha, R. Sudha, S. Rama Reddy, Voltage sag/swell compensation in an interline dynamic voltage restorer., In Emerging Trends in Electrical and Computer Technology (ICETECT), 2011 International Conference on, (2011) 309-314.
[95] A. Elserougi, A. S. Abdel-Khalik, S. Ahmed, A. Massoud, Active and reactive power management of photovoltaic-based interline dynamic voltage restorer in low voltage distribution networks, Energy Conversion Congress and Exposition (ECCE), 2012 IEEE, vol., no., (2012).
[96] A. Hossam-Eldin, A. Elserougi, Renewable energy fed interline DVR for voltage sag mitigation in distribution grids, Electricity Distribution (CIRED 2013), 22nd International Conference and Exhibition on, vol., no., (2013) 1, 4.
DOI: 10.1049/cp.2013.0540
[97] D. M. Vilathgamuwa, H. M. Wijekoon, S. S. Choi, Interline dynamic voltage restorer: a novel and economical approach for multiline power quality compensation, Industry Applications, IEEE Transactions on, vol. 40, no. 6, (2004) 1678, -685.