[1]
Huang C S, Yeh Y K, Axial load behavior of stiffened concrete-filled steel columns, J. Struct. Eng. 09(2002) 1222-1230.
DOI: 10.1061/(asce)0733-9445(2002)128:9(1222)
Google Scholar
[2]
Cai Shao-huai, Modern steel tube confined concrete structure, China Communications Press, Beijing, (2003).
Google Scholar
[3]
Furlong R W, Strength of steel-encased concrete beam-columns, Journal of Structural Division, ASCE. 93(1967)113-124.
DOI: 10.1061/jsdeag.0001761
Google Scholar
[4]
Neogi P K,Sen H K, Chapman J C, Concrete-filled tubular steel columns under eccentric loading, The Sturctural Engineer. 47(1969)187-195.
Google Scholar
[5]
Knowles R B, Par K R, Strength of concrete filled steel tubular co1umns, Journal of Structural division, ASCE. 95(1969) 2565-2587.
Google Scholar
[6]
Knowles R B, Par K R, Axial load design for concrete filled steel tubes, Journal of Structural division, ASCE. 95(1970) 2125-2153.
DOI: 10.1061/jsdeag.0002720
Google Scholar
[7]
Gardner J,Jacobson E R, Structural behavior of concrete filled steel tube, ACI Structure Journal. 07(1967) 404-413.
Google Scholar
[8]
Bridge R Q, Concrete filled steel tubular columns. School of Civil Engineering in University of Sydney, Sydney, (1976).
Google Scholar
[9]
Tomii M, Yoshimaro K, Morishita Y, Experimental study on concrete filled steel tubular stub column under concentric loading, SSRC/ASCE, Washington , (1979).
Google Scholar
[10]
Tomii M, Sakino K, Experimental studies on the ultimate moment of concrete filled square steel tubular beam-columns, Transactions of Japan concrete Institute, (1979).
DOI: 10.3130/aijsaxx.275.0_55
Google Scholar
[11]
Elchalakani M, Zhao X L, Grzebieta R H, Concrete-filled circular steel tubes subjected to pure bending, Journal of Constructional Steel Research. 11(2001)1141-1168.
DOI: 10.1016/s0143-974x(01)00035-9
Google Scholar
[12]
Schneider S P, Axially loaded concrete-filled steel tubes, J. Struct Eng. 10(1998) 1125-1138.
DOI: 10.1061/(asce)0733-9445(1998)124:10(1125)
Google Scholar
[13]
Cai Shaohuai, Di Xiaoian, Behaviour and ultimate strength of concrete-fined steel tubular columns under eccentric loading, Journal of Building Structures. 04 (1985)32-42.
Google Scholar
[14]
Zhong Shan-tong, Structures of concrete-filled steel tube, Tsinghua University Press, Beijing, (2003).
Google Scholar
[15]
Han Lin-hai. Structures of concrete-filled steel tube columns, Science Press, Beijing, (2007).
Google Scholar
[16]
Tao Zhong, Han Linhai, Zheng Yongqian, Huang Hong, Flexural behaviors of concrete-filled double-skin steel tubes, Industrial Construction. 05(2004)6-11.
Google Scholar
[17]
Chen Baochun, Wei Jiangang, Lin Jiayang, Experimental study on concrete filled steel tubular arch with one rib under spatial loads, Journal of Building Structures. 23( 2005) 99-106.
Google Scholar
[18]
Sheng Hongfei, The nonlinear analysis of concrete filled steel tubular half trough arch bridge without wind brace, Journal of Harbin University of Civil Engineering and Architecture. 4(1997) 103-108.
Google Scholar
[19]
Zhao Junhai, Gu Qiang, Ma Shufang. The study of the axial compressive of concrete-filled steel tube based on the twin shear unified strength theory, Engineering Mechanics. 19(2002) 32-35.
Google Scholar
[20]
Hsuan T H, ASCE M, Huang C S. Nonlinear analysis of axially loaded concrete-filled tube columns with confinement effect, J. Struct. Eng. 10(2003)1329-1332.
DOI: 10.1061/(asce)0733-9445(2003)129:10(1322)
Google Scholar
[21]
ABAQUS Inc. ABAQUS theory manual and user manuals, Version 6. 5, ABAQUS Inc, (2004).
Google Scholar